MAC table

MAC address table sets the correspondence between MAC addresses and device interfaces and is used for data packet routing. Routers support table capacity up to 128K of MAC addresses and reserve specific MAC addresses for the system use.

Learning mode

MAC address table may contain either static addresses or addresses learnt during data packet transition through the device.

Learning involves registration of packet source MAC addresses with their binding to ports and VLANs. Afterwards, this data is used for incoming packet routing. Registered MAC address lifetime is limited. Administrator may adjust this setting.

If destination MAC address specified in the packet that was received by the device is not listed in the table, this packet will be sent further as a broadcast packet within L2 segment of the network.

Scroll Pagebreak

Second-layer functions of OSI model

...

Security zones

All router interfaces are distributed by security areas.

For each zone pair, you can set the rules that determine the possibility of data transmission between zones, data traffic filtering rules.

Data filtering

For each zone pair, you can specify the rule set that manages the filtering process for data transmitted through the router.

Device command interface provides appropriate means for detailed configuration of the traffic classification rules and to apply the resulting solution for traffic transmission.

Scroll Pagebreak

Main specifications

Table 8 lists main specifications of the router.

Table 8 – Main specificationsscroll-pagebreak


General parameters

Interfaces



























WLC-15

4 × Ethernet 10/100/1000BASE-T

2 × 1000BASE-X (SFP)

1 × Console port RJ-45

1 × USB 2.0

1 × HDD slot

WLC-30

4 × Ethernet 10/100/1000BASE-T

2 × 10GBASE-R (SFP+)/1000BASE-X

1 × Console port RJ-45

1 × USB 3.0

1 × USB 2.0

1 × HDD slot

1 × microSD card slot

WLC-3200

12 × 1000BASE-X/10GBASE-R/25GBASE-R

1 × Console RS-232 (RJ-45)

1 × OOB port

1 × USB 2.0

1 × microSD card slot

ESR-3200

12 × 1000BASE-X/10GBASE-R/25GBASE-R

1 × Console RS-232 (RJ-45)

1 × OOB port

1 × USB 2.0

1 × microSD card slot

ESR-3100

8 × Combo Ethernet 10/100/1000BASE-T/1000BASE-X 

8 × 10GBASE-R/1000BASE-X (SFP+/SFP)

1 × Console RS-232 (RJ-45)

2 × USB 3.0

1 × SD card slot

ESR-1700

4 × Combo Ethernet 10/100/1000BASE-T/1000BASE-X

8 × 10GBASE-R/1000BASE-X (SFP+/SFP)

2 × Hard disk installation slot

1 × Console RS-232 (RJ-45)

1 × OOB port

2 × USB 2.0

ESR-1511

4 × Combo Ethernet 10/100/1000BASE-T/1000BASE-X 

4 × Ethernet 10/100/1000BASE-T (RJ-45)

4 × 10GBASE-R/1000BASE-X (SFP+/SFP)

2 × 40GBASE-X (QSFP+) 

1 × Console RS-232 (RJ-45)

1 × OOB port

2 × USB 2.0

1 × SD card slot

ESR-1500

4 × Combo Ethernet 10/100/1000BASE-T/1000BASE-X 

4 × Ethernet 10/100/1000BASE-T (RJ-45)

4 × 10GBASE-R/1000BASE-X (SFP+/SFP)

1 × Console RS-232 (RJ-45)

1 × OOB port

2 × USB 2.0

1 × SD card slot

ESR-1200

4 × Combo Ethernet 10/100/1000BASE-T/1000BASE-X 

12 × Ethernet 10/100/1000BASE-T (RJ-45)

8 × 10GBASE-R/1000BASE-X (SFP+/SFP)

1 × Console RS-232 (RJ-45)

2 × USB 2.0

1 × SD card slot

ESR-1000

24 × Ethernet 10/100/1000BASE-T (RJ-45)

2 × 10GBASE-R/1000BASE-X (SFP+/SFP)

1 × Console RS-232 (RJ-45)

2 × USB 2.0

1 × SD card slot

ESR-200

4 × Combo Ethernet 10/100/1000BASE-T/1000BASE-X 

4 × Ethernet 10/100/1000BASE-T (RJ-45)

1 × Console RJ-45

1 × USB 3.0

1 × USB 2.0

1 × SD card slot

ESR-100

4 × Combo Ethernet 10/100/1000BASE-T/1000BASE-X 

1 × Console RS-232 (RJ-45)

1 × USB 3.0

1 × USB 2.0

1 × SD card slot

ESR-30

4 × Ethernet 10/100/1000BASE-T (RJ-45)

2 × 10GBASE-R/1000BASE-X (SFP+/SFP)

1 × Console RS-232 (RJ-45)

1 × USB 3.0

1 × USB 2.0

1 × microSD card slot

ESR-21

8 × Ethernet 10/100/1000BASE-T (RJ-45)

4 × 1000BASE-X (SFP)

3 × Serial port RS-232

1 × Console RS-232 (RJ-45)

1 × USB 3.0

1 × USB 2.0

1 × SD card slot

ESR-20

2 × Combo Ethernet 10/100/1000BASE-T/1000BASE-X 

2 × Ethernet 10/100/1000BASE-T (RJ-45)

1 × Console RS-232 (RJ-45)

1 × USB 3.0

1 × USB 2.0

1 × SD card slot

ESR-15

4 × Ethernet 10/100/1000BASE-T (RJ-45)

2 × 1000BASE-X (SFP)

1 × Console RS-232 (RJ-45)

2 × USB 2.0

ESR-14VF

8 × Ethernet 10/100/1000BASE-T (RJ-45)

1 × 1000BASE-X (SFP)

1 × Console RS-232 (RJ-45)

4 × FXS

2 × USB 2.0

ESR-12VF

8 × Ethernet 10/100/1000BASE-T (RJ-45)

1 × 1000BASE-X (SFP)

1 × Console RS-232 (RJ-45)

3 × FXS

1 × FXO

2 × USB 2.0

ESR-12V

8 × Ethernet 10/100/1000BASE-T (RJ-45)

1 × Console RS-232 (RJ-45)

3 × FXS

1 × FXO

2 × USB 2.0

ESR-10

4 × Ethernet 10/100/1000BASE-T (RJ-45)

2 × 1000BASE-X (SFP)

1 × Console RS-232 (RJ-45)

2 × USB 2.0

Types of optical transceivers

WLC-15

1000BASE-X SFP

WLC-30

1000BASE-X SFP

10GBASE-R SFP+

WLC-3200

1000BASE-X SFP

10GBASE-R SFP+

25GBASE-R SFP28

ESR-3200

1000BASE-X SFP

10GBASE-R SFP+

25GBASE-R SFP28

ESR-1511

1000BASE-X SFP

10GBASE-R SFP+

40GBASE-X QSFP+

ESR-1700

ESR-3100

ESR-1500

ESR-1200

ESR-1000

ESR-30

1000BASE-X SFP

10GBASE-R SFP+

ESR-200

ESR-100

ESR-21

ESR-20

ESR-15

ESR-14VF

ESR-12VF

ESR-10

1000BASE-X SFP

ESR-151000BASE-R SFP+

Duplex or half-duplex interface modes

  • duplex and half-duplex modes for electric ports
  • duplex mode for optical ports

Maximum bandwidth in
L2 mode (hardware switching)

ESR-1700

ESR-1511

ESR-1500

ESR-1200

160 Gbps

ESR-1000

88 Gbps

Data transfer rate

WLC-15

  • electrical interfaces 10/100/1000Mbps
  • optical interfaces 1 Gbps
WLC-30
  • electrical interfaces 10/100/1000Mbps
  • optical interfaces 1/10 Gbps

WLC-3200

ESR-3200

  • optical interfaces 1/10/25 Gbps
ESR-1511
  • electrical interfaces 10/100/1000Mbps
  • optical interfaces 1/10/40 Gbps

ESR-3100

ESR-1700

ESR-1500

ESR-1200

ESR-1000

  • electrical interfaces 10/100/1000Mbps
  • optical interfaces 1/10Gbps

ESR-200

ESR-100

ESR-21

ESR-20

ESR-15

ESR-14VF

ESR-12V(F)

ESR-10

  • electrical interfaces 10/100/1000Mbps
  • optical interfaces 1Gbps

Number of VPN tunnels


WLC-3200

ESR-3200

ESR-3100

ESR-1700

ESR-1511

ESR-1500

ESR-1200

ESR-1000

500

WLC-30

ESR-200

ESR-100

ESR-30

ESR-21

ESR-20

250

WLC-15

ESR-15

ESR-14VF

ESR-12V(F)

ESR-10

10

Number of static routes

WLC-30

WLC-3200

ESR-3200

ESR-3100

ESR-1700

ESR-1511

ESR-1500

ESR-1200

ESR-1000

ESR-200

ESR-100

ESR-30

ESR-21

ESR-20

11k

WLC-15

ESR-15

ESR-14VF

ESR-12V(F)

ESR-10

1k

Number of concurrent sessions

WLC-3200

ESR-3200

ESR-3100

ESR-1700

ESR-1511

ESR-1500

ESR-1200

ESR-1000

512k

WLC-30

ESR-200

ESR-100

ESR-30

ESR-21

ESR-20

256k

ESR-15

ESR-14VF

ESR-12V(F)

ESR-10

4k

VLAN support

up to 4k active VLANs according to 802.1Q

Number of BGPv4/BGPv6 routes

WLC-3200

ESR-3200

ESR-3100

ESR-1700

ESR-1511

ESR-1500

ESR-1200

ESR-1000

5M

WLC-30

ESR-200

ESR-100

ESR-30

ESR-21

ESR-20

2.5M

WLC-15

ESR-15

ESR-14VF

ESR-12V(F)

ESR-10

1M

Number of OSPFv2/OSPFv3/IS-IS routes

WLC-3200

ESR-3200

ESR-3100

ESR-1700

ESR-1511

ESR-1500

ESR-1200

ESR-1000

500k

WLC-30

ESR-200

ESR-100

300k

WLC-15

ESR-30

ESR-21

ESR-20

ESR-15

ESR-14VF

ESR-12V(F)

ESR-10

30k

Number of RIP/RIPng routes

WLC-30

WLC-3200

ESR-3200

ESR-3100

ESR-1700

ESR-1511

ESR-1500

ESR-1200

ESR-1000

ESR-200

ESR-100

ESR-30

ESR-21

ESR-20

10k

WLC-15

ESR-15

ESR-14VF

ESR-12V(F)

ESR-10

1k

MAC address table


ESR-1700

ESR-1511

ESR-1500

ESR-1200

128k entries

WLC-3200

ESR-3200

ESR-1000

16k entries

WLC-15

WLC-30

ESR-3100

ESR-200

ESR-100

ESR-30

ESR-21

ESR-20

ESR-15

ESR-14VF

ESR-12V(F)

ESR-10

2k bridge entries

FIB size





ESR-1700

3.0M

WLC-3200

ESR-3200

ESR-3100

ESR-1511

ESR-1500

ESR-1200

ESR-1000

1.7M

WLC-30

ESR-200

ESR-100

ESR-30

ESR-21

ESR-20

1.4M

WLC-151M

ESR-15

ESR-14VF

ESR-12V(F)

ESR-10

800k

VRF Lite

32

L3 interfaces

WLC-30

WLC-3200

ESR-3200

ESR-3100

ESR-1700

ESR-1500

ESR-1511

ESR-1200

ESR-1000

ESR-200

ESR-100

ESR-30

ESR-21

ESR-20

4000

WLC-15

ESR-15

ESR-14VF

ESR-12V(F)

ESR-10

200

Compliance

IEEE 802.3 10BASE-T Ethernet

IEEE 802.3u 100BASE-T Fast Ethernet

IEEE 802.3ab 1000BASE-T Gigabit Ethernet

IEEE 802.3z Fiber Gigabit Ethernet

IEEE 802.3ba 40GBASE-SR4, 40GBASE-LR4

ANSI/IEEE 802.3 Speed autodetection

IEEE 802.3x Data flow control

IEEE 802.3ad LACP link aggregation

IEEE 802.1q VLAN virtual local networks

IEEE 802.1v

IEEE 802.3ac

IEEE 802.3ae

IEEE 802.1D

IEEE 802.1w

IEEE 802.1s

Control

Local control

CLI

Remote control

TELNET, SSH

Physical specifications and ambient conditions

Power supply

ESR-1700

AC: 176–264 V, 50–60 Hz

DC: 36–72 V

Power options:

  • single AC or DC power supply;
  • two AC or DC power supplies with hot swapping.


WLC-3200

ESR-3200

ESR-3100

ESR-1511

ESR-1500

ESR-1200

ESR-1000

AC: 100–240 V, 50–60 Hz

DC: 36–72 V

Power options:

  • single AC or DC power supply;
  • two AC or DC power supplies with hot swapping.

WLC-15

WLC-30

ESR-200

ESR-100

ESR-30

ESR-21

ESR-20

ESR-14VF

ESR-12V(F)

AC: 100–264 V, 50–60 Hz

ESR-15220 V/12 V, 2 A DC power adapter

ESR-10

220 V/12 V, 1.5 A DC power adapter

Maximum power consumption:


WLC-3200

ESR-3200

118 W

ESR-3100123 W

ESR-1700

 250 W

ESR-1511

128 W

ESR-1500

125 W

ESR-1200

85 W

ESR-1000

75 W

ESR-200

25 W

ESR-100

20 W

WLC-30

ESR-30

26 W

ESR-21

32 W

ESR-20

25 W

WLC-15

ESR-15

18 W

ESR-14VF

ESR-12V(F)

22 W

ESR-10

9 W

Weight



WLC-15

2.7 kg

WLC-302.934 kg
WLC-32006.08 kg
ESR-32005 kg

ESR-3100

4.34 kg

ESR-170012 kg

ESR-1511

ESR-1500

7 kg

ESR-1200

5.5 kg

ESR-1000

3.6 kg

ESR-200

ESR-100

2.5 kg

ESR-301.8 kg

ESR-21

3.15 kg

ESR-20

2 kg

ESR-150.325 kg

ESR-14VF

ESR-12V(F)

ESR-10

1 kg

Dimensions (W × H × D)




WLC-15

430 × 44 × 226 mm

WLC-30430 × 44 × 225 mm
WLC-3200430 × 44 × 330 mm

ESR-3200

ESR-3100

430 × 44 × 330 mm
ESR-1700 440 × 88 × 490 mm

ESR-1511

ESR-1500

430 × 44 × 425 mm

ESR-1200

ESR-1000

430 × 44 × 352 mm

ESR-200

ESR-100

310 × 44 × 240 mm

ESR-21

430 × 44 × 225 mm

ESR-30

ESR-20

267 × 44 × 212 mm

ESR-15230 × 32 × 133 mm

ESR-14VF

ESR-12V(F)

267 × 43.6 × 160.5 mm

ESR-10

185 × 32 × 118 mm

Operating temperature range

WLC-30

WLC-3200

ESR-3200

ESR-3100

ESR-1700

ESR-1511

ESR-1500

ESR-1200

ESR-1000

ESR-200

ESR-100

ESR-30

ESR-21

ESR-20

-10 to +45 °C

WLC-15

ESR-15

ESR-14VF

ESR-12V(F)

ESR-10

0 to +40 °C

Storage temperature range

-40 to +70 °C

Operation relative humidity (non-condensing)

up to 80 %

Storage relative humidity (non-condensing)

from 10 to 95 %

Lifetime

at least 15 years

...

Side panels of the device have air vents for heat removal. Do not block air vents. This may cause the components to overheat, which may result in device malfunction. For recommendations on device installation, see section Installation and connection.

Scroll Pagebreak

WLC-30 design

WLC-30 front panel

...

Front panel element

Description

1

110-250 V АC 50–60 Hz

Power source.

2

Power

Device power LED.

Status

Current device status LED.

Alarm

Alarm LED.

User

LED used for custom scripts that can be assigned in the device configuration mode.

3

F

Functional key that reboots the device and resets it to factory default configuration:

  • Pressing the key for less than 10 seconds reboots the device;
  • Pressing the key for more than 10 seconds resets the terminal to factory settings.

4

Console

Console port RS-232 (RJ-45) for local management of the device.

5

microSD

microSD-card port.

6

USB1

USB 2.0 port for USB devices connection.

7

USB2

USB 3.0 port for USB devices connection.

8

[1 .. 4]

4 ports of Ethernet 10/100/1000BASE-T.

9

XG1, XG2

2 ports of 10GBASE-R (SFP+)1000BASE-X.

10HDDConnector for HDD installation.

Scroll Pagebreak

WLC-30 rear panel

The rear panel of WLC-30 is depicted in below.

...

Side panels of the device have air vents for heat removal. Do not block air vents. This may cause the components to overheat, which may result in device malfunction. For recommendations on device installation, see section Installation and connection.

Scroll Pagebreak

WLC-3200 design

WLC-3200 front panel

...

Front panel element

Description

1






Status

Current device status LED.

Alarm

Alarm LED.

UserLED used for custom scripts that can be assigned in the device configuration mode.
FlashActivity of exchange with data storage  microSD card or USB Flash.

Power

Device power LED.

Master

Failover mode operation LED (is not supported in the current version).

Fan

Fan operation LED.

RPS

Redundant power supply LED.

2

F

Functional key that reboots the device and resets it to factory default configuration:

  • Pressing the key for less than 10 seconds reboots the device;
  • Pressing the key for more than 10 seconds resets the terminal to factory settings.
3OOB

Ethernet port only used for software updates via the U-Boot boot loader. This port is not used for remote access and control.

ConsoleConsole port RS-232 (RJ-45) for local management of the device.

4

microSD

microSD-card port.

5USBUSB 2.0 port for USB devices connection.
6

[1 .. 12]

Slots for 25G SFP28/10G SFP+/1G SFP transceivers.
7HDDConnector for HDD installation.

Scroll Pagebreak

WLC-3200 rear panel

The rear panel of WLC-3200 is shown in the picture below.

...

Side panels of the device have air vents for heat removal. Do not block air vents. This may cause the components to overheat, which may result in device malfunction. For recommendations on device installation, see section Installation and connection.

Scroll Pagebreak

ESR-3200 design

ESR-3200 front panel

...

Description

1

Main power supply.

2

Earth bonding point of the device.

3

Hot-swappable removable ventilation modules.

4

5

Place for installation of a redundant power supply.

...


ESR-3200 side panels

The side panel layout of ESR-3200 is depicted in figures below.

...

Table 57 – Light indication of copper and SFP interface status

SPEED indicator is lit

LINK/ACT indicator is lit

Ethernet interface state

Off

Off

Port is disabled or connection is not established

Off

Solid on

10 Mbps or 100 Mbps connection is established

Solid on

Solid on

1000 Mbps connection is established

X

Flashes

Data transfer is in progress

Figure 71 – Location of SFP connector indicators

...

Table 58 – Status of system indicators

Indicator name

Indicator function

LED State

Device State

Power

Device power LED.

Green

Device power is normal operation state. Main power supply, if installed, is operational. The main software is uploaded.

Red

The main software is not loaded.

Off

Device internal power supply failure.

Status

Current device status LED.

Green

Device is in normal operation state.

Red

Device is booting up the software.

Alarm

Alarm LED.

-

-

User

Used for custom scripts that can be assigned in the device configuration mode

-

-

ESR-12V(F) light indication

...