Wireless access point

WB-15-W2
User manual,  
Firmware version 1.2.1   (02.2020)  

IP address: http://192.168.1.1
User Name: admin
Password: password



|| DeviceType | Wireless access point |
|| DeviceName | WB-15-W2 |
|| DocTitleMain |  |
|| DocTitleAdditional | User manual |
|| fwversion | 1.2.1 |
|| issueDate | 02.2020 |
|| ipaddr | 192.168.1.1 |
|| username | admin |
|| password | password |


Introduction

Annotation

WB-15-W2 is an all-weather wireless Wi-Fi access point with LTE support and a channel redundancy feature for connecting network equipment to the Internet or departmental/corporate networks. The device supports router mode, monitoring the quality of connection with the base station, traffic shaping.

This manual specifies intended purpose, main technical parameters, design, installation procedure, safe operation rules and installation recommendations and also specifies settings that available in WEB interface of the device.

Symbols

Notes and warnings

Notes contain important information, tips or recommendations on device operation and setup.


Warnings are used to inform the user about harmful situations for the device and the user alike, which could cause malfunction or data loss.

Device description

Purpose

WB-15-W2 is an all-weather wireless Wi-Fi access point with LTE support and a channel redundancy feature for connecting network equipment to the Internet or departmental/corporate networks. The device supports router mode, monitoring the quality of connection with the base station, traffic shaping.

WB-15-W2 is designed in a housing with an IP-54 protection, which allows you to operate the device in hard weather conditions.

Power is supplied through the terminals (in the car) or using Passive PoE technology.

Device specification

Interfaces:

Device is powered through a 24V PoE injector from a 220V network, or through a DC power adapter.

Do not use an injector with voltage different from 24V so as not to break down the device!

Functions:

WLAN capabilities:

Network functions:

QoS functions

Security:

WB-15-W2 application diagram is shown oh the figure below. 

Technical features

Technical features

Ethernet interface parameters

Number of ports

1

Electrical connector

RJ-45

Data rate, Mbps

10/100

Standards

BASE-T

2G/3G/4G interface parameters

Frequency ranges

4G LTE FDD: B1, B3, B5, B7, B8, B20
4G LTE TDD: B40
3G UMTS: B1, B8
2G GSM: 850M, 900M, 1800M, 1900M

Data transfer rate1

4G LTE FDD (Cat 4): 150 Mbps (DL) / 50 Mbps (UL)
4G LTE TDD (Cat 4): 130 Mbps (DL) / 35 Mbps (UL)
3G DC-HSPA+: 42 Mbps (DL) / 5,76 Mbps (UL)
2G EDGE: 384 Kbps (DL) / 384 Kbps (UL)

Maximum transmitter power2

4G LTE: up to 23 dBm
3G UMTS: up to 23 dBm
2G GSM: up to 33 dBm

Wireless interface parameters

Standards

802.11b/g/n

Frequency range, MHz

2400– 2480 MHz

Modulation

ССK, BPSK, QPSK, 16QAM, 64QAM

Operating channels2

802.11b/g/n: 1-13 (2412–2472 MHz)

Data transfer rate1, Mbps

802.11n: up to 300 Mbps

Maximum transmitter output power2

2.4 GHz: up to 18 dBm

Receiver sensitivity

2.4 GHz: up to -90 dBm

Security

64/128/152-bit WEP encryption of the data,

WPA/WPA2 data encryption

Control

Remote control

WEB, Telnet, SSH

General parameters

Processor

Realtek RTL8197FS

RAM

128 MB

Flash memory

32 MB

Power supply

Passive PoE 24 V
DC 9-36 V

Max. power consumption

8 W

Range of operation temperatures

from -45 to +60°С

Ingress Protection Marking

IP54

Dimensions

88x232,5x47 mm


The maximum wireless data rate is defined according to standards. The real bandwidth can be different. Conditions of the network, environment, the amount of traffic, building materials and constructions and network service data can decrease the real bandwidth. The environment can influence on the network coverage range.

The number of channels and the value of the maximum output power will vary according to the rules of radio frequency regulation in your country. 

Design

WB-15-W2 housed in a plastic case, industrial version. The size of the device: 88x232.5x47 mm. The layout of WB-15-W2 is shown in the figure below. 

Under the cover at the bottom of the device are located: factory reset button (F), slot for installing two 2G/3G/4G nano-SIMs, 10/100Base-T (Ethernet) port for connecting to an internal network and Passive PoE power, socket for connecting 9-36 VDC power, 1 SMA type connector (female) for connecting an external GPS antenna.

Light indication

The layout of WB-15-W2 indication panel is shown in the figure below.

The LED indicators located on the front panel show the current state of the WB-15-W2. The list of indicators and their description is shown in the table below.

LED

LED status

Description




Power – device power and operation status LED

solid green

the device power supply is enabled, connected to the mobile network, normal operation

solid orange

the device is not connected to the mobile network

solid red

the device is loading

 

LAN – ethernet interface port indicator

solid green

the channel between Ethernet interface of WB-15-W2 and connected device is active

flashes

packet data transmission between Ethernet interface of WB-15-W2 and connected device

Wi-Fi – wireless Wi-Fi interface indicator

solid green

at least one VAP is enabled on the device

Indicator of link level from a cellular provider base station (RSSI)

solid red

the signal level is less than -81 dBm

solid yellow

the signal level is less than -69 dBm  

solid green

the signal level is more or equal to -69 dBm


none of the indicators is on

no signal, the device is not connected to the mobile network

The device schematic structure


Reset to the default settings

You can reset the device configuration using the «F» button on the device: When the device is loaded, press and hold the «F» button (approximately 10–15 seconds) until «Power» indicator is flashing orange. Device will be rebooted automatically. DHCP server will be launched by default (clients connected via Ethernet will receive address in the range from 192.168.1.2 to 192.168.1.254 with subnet mask 255.255.255.0). The device address is 192.168.1.1/24. User Name/Password to access via web interface: admin/password.

Delivery package

The WB-15-W2 standard delivery package includes:

Installation order

This section describes the safety measures, installation procedure and process of turning WB-15-W2 on.

Safety rules

  1. Do not open the device case. There are no user serviceable parts inside.
  2. Do not install the device during a thunderstorm. There is a risk of lightning stroke.
  3. You must follow requirements for voltage, current and frequency specified in the user manual.
  4. Measuring devices and computer must be grounded before connecting to the device. The electric potential differnce between devices' cases should not exceed 1 V.
  5. Make sure that all the cables are intact and they are reliably attached to connectors.
  6. You should satisfy established standards and requirements for working at height during the device installation on the high-rise constructions.
  7. The device exploitation should be performed by specially prepared engineering and technical personnel.
  8. Connect only to operational service equipment.

Installation recommendations

  1. Recommended location for device installation: fix on a mast/pole/wall.
  2. Before you install and enable device, check the device for visible mechanical defects. If defects are observed, you should stop the device installation, draw up corresponding act and contact the supplier.
  3. Install the device on communications mast/pole/wall in the way that the Ethernet port is pointed down.
  4. During the device installation to provide Wi-Fi coverage area with the best characteristics take into account the following rules:
    1. Install the device in the center of the intended wireless coverage area;
    2. Do not install the device near (about 2 m) electrical and radio devices.
    3. Use of radio phones and other devices, which work at 2.4 GHz, within the range of your Wi-Fi wireless network is not recommended;
    4. Obstacles in the form of glass/metal constructions, brick/concrete walls, water cans and mirrors can significantly reduce Wi-Fi action radius.
  5. When mounting the device, you should pay attention to the location of the towers of the cellular base stations of providers whose SIM cards will be used in the device, and place the device as close to them as possible (or, if you use a sector antenna, direct the antenna to the base station).

WB-15-W2 mounting

Pre-tuning

Before installing, proceed pre-tuning of the device:

1. Insert 1 or 2 SIM cards into the slot (as shown in the figure below). SIM1 is active by default.

2. Connect the power supply (points 3, 4 in the Installation procedure section).

3. Ensure the 3G/4G network is available: RSSI indicators should be on (network connection will occur 1-2 minutes after the device boots up).

4. Configure the device: follow the algorithm from the Configuration example section.

Please note that for the device to automatically connect to the mobile network, a SIM card must be inserted into the device before power is supplied to it.

Mounting algorithm

1. Attach the bracket to the device with the screws provided, as shown in the figure below.

  

2. Install the device on communications mast/pole pointing Ethernet port down as it is shown on the figure below. Attach the device using clamps supplied in the device package. Comply the safety rules and recommendations given in Safety rules and Installation recommendations.

3. Remove the bottom cover which close bottom panel and connect the Ethernet cable to the PoE port. 

4. If the device will be supplied by a DC network, connect the contacts of the DC power supply (9-36V), observing the polarity.

5. Close the bottom cover.

6. Connect the OMNI antennas to the device. If using a sector antenna, connect it using cable assemblies.

7. Adjust the position of the antenna so that it faces toward the base station.

8. Connect Ethernet cable of your WB-15-W2 to LAN port of PoE injector (Passive PoE 24V). If the device is connected to a DC power supply, if you need to connect to the switch, make sure that PoE is disabled on it.

9. If you using PoE injector connect it to 220 V power supply network using the cable.

To avoid damage to the device, it is recommended to use lightning protection!

Managing the device through web interface

Getting started

To start, you need to connect the device through a browser:

1. Open a web browser (web-page explorer), for example, Firefox, Opera, Chrome.

2. Enter IP-address of the device to the browser address line. 


The default IP-address of the device – 192.168.1.1, subnet mask – 255.255.255.0. DHCP server is launched by default (clients connected to the LAN will receive address in the range from 192.168.1.2 to 192.168.1.254).

Factory settings: username – admin, password – password.

If connection is successful, request form with user name and password will be displayed on a browser window.

3. Enter your username into ‘Login’ and password into ‘Password’ field.

4. Click the ‘Log in’ button. A menu for monitoring the status of the device will open in a browser window.

5. If necessary, you can switch the display language information. Russian and English languages are available for WEB interface.

Applying configuration and discarding changes

1. Applying configuration 

After clicking the  button the configuration is saved to flash-memory of the device and new settings apply. All the settings come into operation without device rebooting.

Visual indication of the process current status of the setting application process is realised in the WEB interface.

Image

State description

After pressing «Apply», the process of settings saving to device memory is launched. This is indicated by the  icon in the tab name and on the «Apply» button.

Successful settings saving and application are indicated by the  icon in the tab name.

2. Discarding changes

Click  to discard changes.

You can discard changes only before pressing «Apply» button. If you press «Apply» button, all the changed parameters will be applyed and saved to device memory.

Main elements of the web interface

Navigation elements of the WEB interface are shown on the figure below.

User interface window is divided into five general areas:

  1. Menu tabs categorize the submenu tabs: Monitoring, Mobile Network, LAN, Radio, VAP, System.
  2. Interface language selection and Logout button designed to to end a session in the WEB interface under a given user.
  3. Submenu tabs allow you to control settings field.
  4. Devcie configuration field displays data and configuration.
  5. Information field displays current firmware version.

The «Monitoring» menu

In the «Monitoring» menu you can view the current system state.

The «Device Information» submenu

The «Device Information» submenu displays main WB-15-W2 parameters.

The «Network Information» submenu

In the «Network Information» submenu you can view common network settings of the device.

DHCP server:

ARP:
The ARP table contains information about the alignment between the IP and MAC addresses of neighboring network devices:

Routes:

The «Mobile network» submenu

In the «Mobile network» submenu you can view the current status and parameters of the connection to the mobile network.

Channel redundancy:

The «Interfaces» submenu

WAN Status:

Ethernet:

The «Wi-Fi» submenu

The «Wi-Fi» submenu displays information about current radio interface configuration and the status of connected Wi-Fi clients.

Wi-Fi Status:

Wi-Fi clients:

The «Scan Environment» submenu

In the «Scan Environment» submenu, scanning of the surrounding radio is carried out and detection of neighboring access points.

After clicking on the «Scan» button, the process will be launched. After the scan is completed, a list of detected access points and information about them will appear:

Please note that during the environment scan, the device’s radio interface will be disabled, which will make it impossible to transfer data to Wi-Fi clients during the scan.

The «Mobile Network» menu

In the «Mobile Network» menu, the 2G/3G/4G interface is configured.

The «Common» submenu

To apply a new configuration and save setting to non-volatile memory, press «Apply». Press «Cancel» to discard the changes.

The «Channel Reservation» submenu

In the «Channel Reservation» submenu, you can configure the switching of the active SIM card if the quality of the connection with the current active SIM card does not meet the specified parameters. The channel quality control mechanism is based on sending ICMP messages to a server and analyzing the resulting statistics.

To apply a new configuration and save setting to non-volatile memory, press «Apply». Press «Cancel» to discard the changes.

Please note that switching the active SIM card, or moving to the next ping-server, is carried out in the case when at least one of the received quality parameters does not satisfy the specified conditions.
In case there is a switch to a backup SIM card, this configuration will be automatically saved on the device. That is, when the device is rebooted, the SIM card that was active immediately before the reboot will be active.

The «IPSec» menu.

The «IPSec parameters»

The «LAN» menu

The «Network» submenu

Network Settings:

DHCP server settings:

Enable – set the flag so that clients connected to Wi-Fi or Ethernet interfaces can get an IP address. Specify the following parameters for the DHCP server:

To apply a new configuration and save setting to non-volatile memory, press «Apply». Press «Cancel» to discard the changes.

Please note that the address pool for issuing to clients must be on the same subnet as the device. A DHCP server issues IP addresses to clients on a LAN subnet, and in this case, the IP address of the device is a gateway for redirecting client requests to the WAN, that is, it performs the function of masquerading.

Static leases

Click the  «Add» button to add static addresses and enter MAC and IP addresses of the client. When connected to the device’s Wi-Fi or Ethernet interfaces, the client with the specified MAC address will be given the specified IP address.

The «Access» submenu

In the «Access» submenu, you can configure access to the device via the web interface, Telnet, SSH, NETCONF and SNMP.

Access via NETCONF is not supported in the current firmware version 1.2.1.

Note that the ports for the HTTP and HTTPS protocols should not have the same value.

WB-15-W2 software allows monitoring status of the device and configuring it via SNMP. In the SNMP submenu, you can configure settings of SNMP agent. The device supports SNMPv1, SNMPv2, SNMPv3.

To change the SNMP settings, check the box next to «SNMP», apply the configuration and then go to the «SNMP configuration» submenu.

The list of objects which are supported for reading and configuration via SNMP is given below:

where Enterprise – 1.3.6.1.4.1.35265.1.56 is Eltex Enterprise identifier.
To apply a new configuration and save setting to non-volatile memory, press «Apply». Press «Cancel» to discard the changes.

The «Radio» menu

In the «Radio» menu you can configure the wireless interface

The «Radio» submenu

In the «Radio» submenu, you can configure the device’s radio interface.

The «QoS» submenu

In the «QoS» submenu, you may configure Quality of Service functions.

To apply a new configuration and save setting to non-volatile memory, press «Apply». Press «Cancel» to discard the changes.

The «Advanced» submenu

In the «Advanced» submenu, you can configure advanced device’s radio interface parameters.

The «VAP» menu

In the «VAP» menu, you configure virtual Wi-Fi access points (VAP).

The «Summary» submenu

The «Summary» submenu displays the settings of all virtual Wi-Fi APs (VAP). You can see the settings of each virtual AP in sections VAP0..3.

To apply a new configuration and save setting to non-volatile memory, press «Apply». Press «Cancel» to discard the changes.

The «VAP» submenu

Common Settings:

Shapers:

Show – display configuration field;

Captive Portal:

RADIUS:

To apply a new configuration and save setting to non-volatile memory, press «Apply». Press «Cancel» to discard the changes.

The «System» menu

In the «System» menu you can configure system, time, change password and update device firmware.

The «Device Firmware Upgrade» submenu

The «Device Firmware Upgrade» submenu is intended for upgrading the device's firmware.

Firmware update

Download the firmware file from https://eltex-co.com/support/downloads/ and save it on your computer. To do this, click the «Choose file» button in the Firmware Image field and specify the path to the firmware file in .tar.gz format. 
To start the update process, you must click the «Start Upgrading» button. The process may take several minutes (its current status will be shown on the page). The device will be automatically rebooted when the update is completed.

Do not switch off or reboot the device during the firmware update.

The «Configuration» submenu

In the «Configuration» submenu, the current configuration is saved to a file and the configuration is downloaded to the device.

Backup Configuration

To save current device configuration to local computer click on the «Download» button.

Restore Configuration

To download the configuration file saved on the local computer, use the Restore Configuration item. To update the device configuration click the «Browse» button, specify a file (in .tar.gz format) and click the «Upload» button. Uploaded configuration will be applied automatically and does not require device reboot.

Note that all the passwords of configuration are encrypted with a key depending on device MAC address. When uploading a configuration from one device to another, you first need to reset the passwords, or change them in the configuration file before downloading to the device (encrypted fields).

Reset to Default Configuration

To reset all the settings to default values, press «Reset» button.


The «Reboot» submenu

To reboot the device, click on the «Reboot» button.

The «Password» submenu

When signing into web interface, administrator (default password: password) has the full access to the device: read/write any settings, full device status monitoring.
To change the password, enter the new password first in the «Password» field, then in the «Confirm Password» field and click the «Apply» button to save the new password.

The «Date and Time» submenu

In the «Date and Time» submenu, you can set the time manually or using the time synchronization protocol (NTP).

Manual:


NTP Server:


To apply a new configuration and store settings into the non-volatile memory, click the «Apply» button. To discard changes click the «Cancel» button.

Пример настройки

1. Connect the PC to the LAN port of the injector (when the device is powered by Passive PoE 24 V), or directly to the Ethernet port of the device (if the device is powered from the DC 9-36V unit);

2. In the address bar of the browser, enter the IP address of the device (default is 192.168.1.1). On a PC, you need to either enable obtaining addresses via DHCP, or set a static IP from the 192.168.1.0/24 subnet;

3. When connection is established successfully, the window with Login and password fields will be displayed. Fill the filds and press «Log in». (By default, login: admin, password: password).

If the window is not displayed, make sure that the PC and the device are in the same subnet. 

4. After connecting the device to the mobile network (1-2 minutes after loading the device, if there is a SIM card in the SIM1 slot), the Monitoring -> Mobile Network menu will display information about the network connection mode, mobile network operator, IMSI of the current SIM card etc. Also, the status LED will turn green.

Please note that for the device to automatically connect to the mobile network, a SIM card must be inserted into the device before power is supplied to it.

From this moment, the device has access to the Internet and can provide services to customers. For further tuning, go to the «Radio» menu.

5. In the «Radio» menu, set the desired Wi-Fi network operation mode (preferably b/g/n), channel width, frequency channel number, radiation power.

To configure VAP settings, go to the «VAP» menu.
To save and apply changes click .

6. In the «VAP» menu, go to one of the four VAPs, turn it on, configure the settings necessary for connecting clients (SSID, security mode, security key, restriction of connected clients).

After completing the configuration, clients will be able to connect to VAP and gain access to the Internet.
To save and apply changes click .

7. To prevent unauthorized access to the device, after making the settings, go to the «System» menu and in the «Password» tab, change the default password value.

To save and apply changes click .

Radar

Configuration example

WB-15-W2(root):/# configure
WB-15-W2(config):/# interface
WB-15-W2(config):/interface# wlan1
WB-15-W2(config):/interface/wlan1/wlan# radio
WB-15-W2(config):/interface/wlan1/wlan/radio# monitor
WB-15-W2(config):/interface/wlan1/wlan/radio/monitor# uplink-interface usb0:ipsec
WB-15-W2(config):/interface/wlan1/wlan/radio/monitor# url http://X.X.X.X (where http://X.X.X.X – address of the server where the messages from the monitor will be forwarded to)
WB-15-W2(config):/interface/wlan1/wlan/radio/monitor# enabled true


WB-15-W2(config):/system
WB-15-W2(config):/system# ap-location location

Parameters description

ParameterDescription
enabled enable monitor mode
mode
  • mac – macro address list issuance mode;
  • tzsp – remote capture via TZSP.
url

URL of the server for uploading macros via HTTP. Used only if mode = mac

server-ipthe IP address of the server to transmit TZSP traffic. Used only only if mode = tzsp
channel-timechannel scan time. Used if fixed-channel = false
allow-broken-packetsallows the analysis of packages received with errors
capture-beaconsselect the traffic reception mode. Either take beacons or everything else.
fixed-channelthe parameter defines whether switching will be performed on all channels (taking into account limit-channels) or will listen only to the currently configured channel
uplink-interfacethe name of the interface through which we will communicate with the server part. The parameter must always be defined
send-intervalperiodicity of sending MAC address table to the server. Used only if mode = mac
max-macsthe maximum size of the MAC address table. Used only if mode = mac
mac-sources

a bit mask to filter the types of packets for which a macro address table is formed. Used only if mode = mac:

  • Bit 0 - Probe Req
  • Bit 1 - Assoc Req
  • Bit 2 - other types of traffic (mainly data)

I.e. if mac-sources = 1 we will track only probe req, if mac-sources = 2 we will track only assoc req, if mac-sources = 7 we will track all three types of packages.


"monitor":{
"enabled":"false",
"mode":"mac",
"url":"http:\/\/172.16.0.16\/",
"server-ip":"172.16.0.16",
"packet-length":"252",
"channel-time":"1000",
"allow-broken-packets":"true",
"capture-beacons":"false",
"fixed-channel":"true",
"uplink-interface":"usb0:ipsec",
"send-interval":"1",
"max-macs":"1000",
"mac-sources":"7"
}

GPS

Information on the current location of the device (in the form of coordinates width, longitude) is displayed in the «GPS» submenu. To obtain this information, you need to connect an external GPS antenna to the device.

WB-15-W2(root):/# configure
WB-15-W2(config):/# geolocation
WB-15-W2(config):/geolocation# workmode gps

You can view the received data with a command:

WB-15-W2(config):/# monitoring location-info

The list of changes

Document version

Issue date

Revisions

Version 1.0

28.02.2020

First issue

Firmware version 1.2.1