This chapter describes the naming rules for MA4000-PX interfaces.
Access node interfaces can be divided into two groups: Ethernet interfaces and GPON interfaces. Ethernet interfaces are used for access node connection to operator's network core. GPON interfaces are used for ONT connections.
Figure 2 – Access node interface name system
For accepted access node interface name system, see Table 4.1.
Table 4.1 – Access node interface name system and numbering
Interface name | Description | Range |
---|---|---|
front-port | PP4X module external uplink interfaces | Specified as: U/P
|
port-channel | LAG of PP4X module uplink interfaces | [1..8] – aggregation group number |
slot-port | Interfaces of the PP4X module for connecting GPONPLC8 modules | Specified as: U/P
|
slot-channel | LAG of PP4X module interfaces for PLC8 modules | [0..15] – PLC8 module number |
stack-port | PP4X module internal stacking interfaces | Specified as: U/P
|
plc-slot-port | PLC8 module interfaces for connection to central switches – PP4X modules | Specified as: SP
|
plc-slot-channel | PLC8 module interface LAG for connection to central switches – PP4X modules | [0..15] – PLC8 module number |
plc-front-port | PLC8 module external management interface (mgmt) | [0..15] – PLC8 module number |
plc-pon-port | PLC8 switch downlink interface connected to GPONOLT | Specified as: SP
|
plc-mgmt-pon-port | PLC8 switch downlink interface connected to GPONOLT designed to control | Specified as: SP
|
gpon-port | PLC8 module external GPON interfaces | Specified as: SP
|
ont | Interfaces for the subscriber-side ONT terminals | Specified as: S/P/I
|