The Line crossing model is designed for notification of entry into a restricted area.
The camera must be located in the same room as the relay it will control, otherwise the relay will not work on recognition/detection. |
In the camera edit, switch to the Video analytics section.
Click Edit on the Line crossing model.

Select the desired camera from the list.

When the sensitivity of the license plate recognition model is high, it may be triggered by noise and distortions not related to the license plate. The sensitivity is adjusted experimentally to ensure guaranteed detection of the license plate in the frame while minimizing false alarms due to noise. An example of an ultra-high sensitivity of 0.01.
|
By default, after creating a crossing line, it is formed as a line located in the center.
Move the switch to the active position, click the Add action button.

Then select the action type — Relay/Record to archive, the required relay from the list and the relay status — Open/Closed/Pass.