Minimum Access mode configuration

The minimum port configuration required for Access mode operation on MES switches:

switchport mode access
switchport access vlan <VLAN_ID>

where <VLAN_ID> is the VLAN number that will be used on the port.

Configuring PoE

PoE (Power over Ethernet) is a technology that makes it possible to power equipment connected to an Ethernet port. Connected equipment must support PoE. It is possible to connect a VP-17P or VP-30P IP phone to a switch with PoE support (e.g., MES2308P) via Ethernet and not connect the phone to a 230 V network with a separate power supply.

By default, PoE is enabled on switch ports and generally does not require configuration.

In some cases, it is convenient to reboot the telephone by turning PoE off and then back on at the port.

power inline never


power inline auto

Configuring Voice VLAN

Most modern telephones can connect other client equipment to the Ethernet network through themselves. As a rule, this method is used to connect a personal computer at the workplace. In this case, the telephone and computer can (and it is recommended to do so) be located in different virtual local area networks (VLANs). To do this, Voice VLAN must be configured for the phone on the switch port.

Example of Voice VLAN configuration:

vlan database
 vlan <VOICE_VLAN_ID>,<DATA_VLAN_ID>
exit
!
interface vlan <VOICE_VLAN_ID>
 name VoIP
exit
!
no lldp med network-policy voice auto
lldp med network-policy 1 voice vlan <VOICE_VLAN_ID> vlan-type tagged up 4
!
voice vlan id <VOICE_VLAN_ID>
voice vlan state oui-enabled
voice vlan oui-table add <MAC_ADDR>
interface <INTERFACE>
 switchport mode access
 switchport access vlan <DATA_VLAN_ID>
 lldp med enable network-policy
 lldp med network-policy add 1          
 voice vlan enable
exit
!

where: