General information

This section describes the procedures for configuring OLT and ONT functionality in the OLT web interface. As an example, let's look at configuring the PON part for OLT LTP-16N and ONTs of the following models: NTU-1, NTU-RG-5421G-Wac, NTU-RG-5520G-Wax,  NTU-SFP-200, similar to the configuration procedure from the CLI. All subscriber terminals in this example are physically connected to the same PON tree on the OLT PON port 1 interface. Service configuration includes the following procedures.

Globally for OLT:

  • Configuring access to the web interface;
  • Configuring the internal OLT switch to receive services from the upstream data network;
  • Configuring service profiles and other ONT service configuration parameters;
  • Configuring additional functionality;
  • The default service model is used: vlan-replace olt-side + traffic model n-to-1.

For ONTs operating in bridge mode: 

  • Creating OLT service profiles to configure ONTs in bridge mode, providing a logical data transmission channel between the OLT and ONTs for specific services;
  • Binding LAN ports to specific ONT services so that end customers connected to the ONT can get services.

For ONTs running in router mode:

  • Creating OLT service profiles to configure ONTs in router mode and forming a logical data transfer channel between the OLT and ONTs for specific services.

Configuring internal ONT interfaces using the built-in OLT ACS server is not covered in this section. ONT configuration using the OLT ACS server is only available via CLI.

Initial configuration of the OLT in terms of management settings for network connection can be performed via the OOB interface or via the console interface. For more information on configuring management parameters, refer to the OLT user documentation.

LTP-16N# configure terminal
LTP-16N(configure)# management ip 10.10.0.20
LTP-16N(configure)# management mask 255.255.0.0
LTP-16N(configure)# management gateway 10.10.0.1
LTP-16N(configure)# management vid 100
LTP-16N(configure)# interface front-port 1
LTP-16N(config)(if-front-1)# vlan allow 100
LTP-16N(configure)# do commit
LTP-16N(configure)# do save
Switching to OLT configuration mode
Specifying the IP address of the OLT in the management network
Specifying the management subnet mask
Specifying the default gateway
Specifying the VLAN for OLT management
Switching to front-port 1 uplink interface configuration mode
Configuring the management VLAN on the uplink interface
Applying the configuration
Saving the changes to non-volatile memory

The web service is disabled by default in OLT configuration. Use the following command to enable it:

LTP-16N# configure terminal
LTP-16N(configure)# ip web enable
LTP-16N(configure)# do commit
LTP-16N(configure)# do save
Switching to OLT configuration mode
Enabling terminal accessibility via IPv4 address for HTTP protocol
Applying configuration
Saving changes to non-volatile memory

After applying this setting, the web interface will be available for use. Connect to the web interface using any web browser. The connection is available both via the network using the configured management IP address http://10.10.0.20 (if the management setting was previously configured via CLI) and via the OOB interface. The default OOB connection address is http://192.168.200.2.

When connecting, a dialog box will open for authorization on the OLT, where you must enter the appropriate login details. A description of the accounts used to access the web interface is provided in the manual for configuring and monitoring the OLT via the web interface.

After successful authorization, the user will be presented with a start page displaying information about the OLT.

Navigation menu on the left sidebar:

- Monitoring. This tab provides information about OLT and ONT;
- ONT list;
- Configuration. This tab provides network settings, NTP and SNMP settings, and profile settings;

- Administration. This tab provides commands for working with OLT and ONT software, as well as settings for working with backups and licenses.

- Operations. This tab provides OLT commands: Save, Reconfigure, Reboot, Default.

Let's look at an example of configuring service profiles and ONT, similar to the one given in the Configuring OLT and ONT in CLI (GPON diagram) .

Configuring basic functionality

Configuring management parameters, interfaces, and VLANs

When changing management parameters from the web interface, it is necessary to first assign a management VLAN to the OLT uplink port. Adding a management VLAN (as well as other service VLANs) to the uplink interface is done in the "Front-ports" tab.

An interface properties icon is available opposite each interface. Clicking on the icon opens the Uplink interface editing window. To add a VLAN, enter the VLAN number or range in the "Vlan Allow" field and click the "+" icon. To remove a VLAN from the interface, enter the VLAN number in the "Vlan Allow" field and click the "-" icon. To apply the changes, click the "Apply" button.

If necessary, the OLT management interface settings can be changed via the web interface. To do this, go to the management settings tab by following the path "Configuration" → "Network Settings" → "Management Interface" and set the OLT network settings.

Changing the management settings will terminate the current web session. To resume work, it is necessary to connect to the new address.

IGMP Snooping settings are not available in the web interface. The IGMP parameters of the OLT's internal switch must be configured from the CLI of the OLT.

Configuring cross-connect service profiles

To configure cross-connect profiles, go to the "Configuration" → "Profiles" → "ONT Profiles" tab, then to the "Cross-connect" section. By default, all types of default profiles are always created on the OLT. The default profile crossconnect1 is created for cross-connect. To add a new profile, use the button.

Configuring cross-connect profiles for NTU-1

Create a cross-connect profile for the HSI service for NTU-1 according to the example below. Change the highlighted parameters; the rest can be left at their default values. Apply the changes.

Configuring cross-connect profiles for NTU-SFP

Create an HSI service cross-connect profile for NTU-SFP according to the example below. Apply the changes.

 

Create an IPTV service cross-connect profile for NTU-SFP according to the example below. Apply the changes.

 

Create a cross-connect profile for the management service (management of the switch that NTU-SFP is connected to) for NTU-SFP according to the example below. Apply the changes.

 

Configuring cross-connect profiles for NTU-RG

Create an HSI service cross-connect profile for NTU-RG as shown in the example below. Apply the changes.

 

Create an IPTV service cross-connect profile for NTU-RG as shown in the example below. Apply the changes.

 

Create a VoIP service cross-connect profile for NTU-RG as shown in the example below. Apply the changes.

 

 Create a cross-connect profile for the service of ONT interaction with OLT's built-in ACS server for NTU-RG according to the example below. Apply the changes.

 

Configure ports sevice profiles

To configure ports profiles, go to the "Configuration" → "Profiles" → "ONT Profiles" tab, then to the "Ports" section. Default profiles of all types are always created on the OLT. The default profile ports1 is created for ports. To add a new profile, use the  button.

Configuring the ports profile for NTU-1

Create a ports profile for NTU-1 according to the example below. Specify the profile name, then change the parameters located under the hidden menu: "GMP Multicast Dynamic Entry" and "LAN Port Settings".

When adding a Dynamic entry, an entry will be added to the table. Specify the correct VLAN ID for the multicast VLAN by editing the cell. If necessary, the range of allowed multicast groups can also be adjusted.

When opening the "LAN Port Settings" menu, a table for editing all possible LAN ports opens. For NTU-1, only LAN port 1 is relevant. Set the required configuration for this port.

Apply the changes you have made.

Configuring the ports profile for NTU-SFP

Create a ports profile for NTU-SFP according to the example below. Specify the profile name, then change the parameters located under the hidden menu: "IGMP Multicast Dynamic Entry" and "LAN Port Settings".

When adding a dynamic entry, an entry will be added to the table. Specify the correct VLAN ID for the multicast VLAN by editing the cell. If necessary, the range of allowed multicast groups can also be adjusted.

When opening the "LAN Port Settings" menu, a table for editing all possible LAN ports opens. For NTU-SFP, only LAN port 1 is relevant. Set the required configuration for this port. The "IGMP Downstream/Upstream Tag Control" parameters remain empty, as the required "Pass" values are the default values.

Apply the changes you have made.

Configuring the ports profile for NTU-RG

Create a ports profile for NTU-RG according to the example below. Change the highlighted parameters; the rest can be left at their default values.

Also add Dynamic entry.

Apply teh changes.

Configuring a built-in ACS server

The settings for the built-in ACS server are not available in the web interface; only the management profile can be configured. The parameters for the built-in OLT ACS server must be configured from OLT CLI.

Configuring the management profile

To configure the management profile, go to the "Configuration" → "Profiles" → "ONT Profiles" tab, then to the "Management" section. By default, all types of default profiles are always created on the OLT. The default management1 profile is created for management. To add a new profile, use the button.

Create a management profile for NTU-RG with information about the built-in ACS server of the OLT as shown in the example below. Change the highlighted parameters and leave the rest of the parameters at their default values. Apply the changes.

Registering ONTs on the OLT and assigning configurations to ONTs

ONTs and their configurations are managed in the "ONT List" tab. This list displays registered and unregistered ONTs. The screenshot below shows an example of this section when there are connected but unregistered ONTs.

It is assumed that the serial number and ONT model are known:

  • ELTX8903488C – NTU-1:rev.C;
  • ELTX92000038 – NTU-RG-5421G-Wac:rev.B;
  • ELTXA1000010 – NTU-RG-5520G-Wax;
  • ELTX1900C004 – NTU-SFP-200.

On the network in operation, this data can be obtained from inventory records or from the billing system.

ONT registration and configuration assignment is performed by clicking the  icon next to ONT. In the pop-up menu, select "Add ONT Configuration." This will open the settings window for the selected ONT.

Adding NTU-1 to the configuration

Register NTU-1 and assign the configuration as shown in the example below. Change the highlighted parameters; the rest can be left at their default values. Apply the changes.

Adding NTU-RG-5520G-Wax to the configuration

Register NTU-RG-5520G-Wax and assign the configuration as shown in the example below. Change the highlighted parameters; the rest can be left at their default values. Apply the changes.

Adding NTU-RG-5421G-Wac to the configuration

Register NTU-RG-5421G-Wac and assign the configuration as shown in the example below. Change the highlighted parameters; the rest can be left at their default values. Apply the changes.

Adding NTU-SFP-200 to the configuration

Register NTU-SFP-200 and assign the configuration as shown in the example below. Change the highlighted parameters; the rest can be left at their default values. Apply the changes.

Checking the ONT status

As a result of the settings made, all ONTs in the list should have the "OK" status and a green status indicator.