Working with the ACS module in the Eltex.EMS GUI

Before starting to work with ACS in the Eltex.EMS GUI, add ACS to the device tree. The procedure for adding ACS to the device tree is described in the ACS documentation – EMS-ACS Interface Interaction Guide.

If the services are configured correctly according to Appendix 1, ONTs should automatically connect to the external ACS server and appear in the list of available devices. To view the list of ONTs, go to the ACS section in the EMS device tree, then to the "Devices" tab. Then, in the ACS operations tree, select the "CPE" → "list" section . For an external ACS server, there is the concept of device classes. A class is a group of devices of different models that are identical in purpose and functionality (ONT, voice gateways, STB, etc.). For ONT, a class called "NTP" is allocated, and all operations with GPON ONT are carried out in this class.

The format for displaying PON serial of the ONT in ACS view differs from the usual CLI. In ACS, serial numbers are always displayed in HEX format.

The list of ONTs registered on the ACS server is presented in the form of a table containing ONT parameters. The key ones are:

Double-clicking the left mouse button on the ONT selected in the list opens the ONT settings editing window.

The following key elements are available in this window:

Adding an ACS profile

To assign an ACS profile to an ONT, the profile must first be added to the ACS server. An ACS profile is added in the "Devices" → "Profiles" section. The workspace of the ACS profile management section looks like this:

By default, ACS always has an empty profile named "0" that does not contain any parameters. This profile is automatically applied to all new ONT servers that connect to ACS.

To create a new ACS profile, select the icon. A window for adding a new profile will appear. Enter the basic information:

After specifying the basic information about the profile, select the "Accept" button.

As a result of these actions, the ACS profile will appear in the general list.

Next, you need to fill in the ACS profile. To switch to profile editing mode, double-click the left mouse button on the selected profile. To insert the contents of the ACS profile, you can use the "Add" and "Insert" buttons.

When you click the button, parameters can be added line by line.

The  button pastes the contents of the clipboard. When using the “Paste” button, the contents of the ACS profile must first be copied to the clipboard from a text editor, for example. When pasting from the clipboard, the profile can be pasted in its entirety.

Pre-made ACS profiles for ONT NTU-RG-5520G-Wax and NTU-RG-5421G-Wac are located in Appendix 2 and Appendix 3, respectively. The profiles in the appendices are in a format in which they are uploaded to the built-in ACS server OLT. Before uploading the profile to an external ACS server, the values “set property” at the beginning of each line and “nocheck” at the end of each line must be deleted from the profile content.

Configuring ONT

After adding the profile to the ACS server, return to the section containing the ONT list ("cpe" → "list").

Then follow these steps:

  1. Go to ONT configuration – select the required device from the ONT list to start the configuration process.
  2. Assign the previously created ACS profile – during the configuration process, assign the previously created ACS profile to the selected ONT.
  3. Apply settings – make sure that all changes have been saved correctly and the settings have been applied.

After the settings have been successfully applied, the assigned ACS profile will be displayed in the general list of ONT devices.

After assigning an ACS profile or private parameters, it is recommended to reset the ONT to factory settings to ensure that the configuration is applied quickly and correctly.