To connect to the EMS server GUI from the provider's workstation, Java17 must be installed on the provider's PC (for current versions of EMS). The connection is established by downloading the applet to the PC via a browser at the following address:
http://<server_ip_ems>:8080/ems/jws
Next, the downloaded jnlp applet file must be run using Java. By default, the admin account without a password is used to access the GUI. The system is accessed by entering the user account name and password. After user identification, a dialog box with a list of permitted actions and nodes or an error message is displayed. Users can configure parameters such as user name, password, role, account expiration date, etc. User configuration is performed in the "Administration" section → "Rights and Users" → "System User Settings".
Let's take a look at the EMS user interface workspace and how to configure the EMS device by performing the same steps for setting up service profiles and ONTs as described in the CLI section of Configuring OLT and ONT in CLI (GPON diagram).
Description of the management system workspace
The EMS user interface workspace consists of the following elements:
- Control panel (1);
- Device tree (2);
- Settings field (3);
- Task field (4).
The layout of these fields is shown in the screenshot.
Adding devices to the object tree
To manage a device, a network node (OLT) must be added to the object tree. This is done by clicking the icon in the object tree. The following information must then be specified:
- Object name – can be anything (corresponding to the hostname, management IP address, etc.);
- Object – the model of the device being added;
- IP address – the management IP address specified on the device;
The object name does not have to match the device hostname. The device name specified when adding it to the tree is only needed to identify the OLT within the EMS system.
The device being added must be accessible via the management IP address from the EMS server. Devices can be grouped in directories by adding an object with the NODE type and placing the network node under this object. Devices can be grouped according to various criteria: by geographical location, by device model, etc. For the device to work correctly, the added device must be configured to send traps to the EMS server IP (see SNMP configuration in the Configuring OLT and ONT in CLI (GPON diagram) section.
After adding the device, the management system will interact with the device using the default community public and private values. If these have been changed, new settings must be specified for this device in EMS. Select the device in the object tree, then go to the "Access" tab, click the edit icon, and specify the correct access parameters.
In addition, for EMS to work correctly with OLT, it is necessary to configure OLT to send traps to the EMS server address. If this has not been done previously in the CLI, it can be configured via EMS after adding the device. In the device tree, select the desired OLT, then go to the "Configuration" tab in the settings field, then to the "Traps" section. In this window, add the trap recipient. A window will open in which the EMS server data will be automatically inserted. If necessary, correct the automatically inserted data and apply the changes.
To update the OLT information, synchronize the device using the button on the control panel. To synchronize all added OLTs, select the root device (EMS) in the device tree when you click the button, or to synchronize a single OLT, select a specific device in the tree. All devices in the tree are synchronized automatically once an hour. OLT status information is also updated in real time when the server receives SNMP trap messages from the OLT about various events.
Configuring OLT and ONT
Let's look at an example of configuring an OLT and connected ONTs (ONT registration procedures, service configuration). The configuration will be performed in the same way as the OLT configuration in CLI, described in the Configuring OLT and ONT in CLI (GPON diagram) section.
Configuring cross-connect profiles
To configure cross-connect profiles, select the desired OLT in the device tree, then go to the "Configuration" tab in the settings field, then to the "Profiles" section and select the "CrossConnectProfile" type. Default profiles of all types are always created on the OLT. The default profile crossconnect1 is created for cross-connect. To add a new profile, use the button. The configuration tab for this section looks like this:
Configuring cross-connect for NTU-1
Create a cross-connect profile for NTU-1 according to the example below. Apply the changes (click the "Accept" button).
Configuring cross-connect for NTU-SFP
Create a cross-connect profile for the IPTV service for NTU-SFP according to the example below. Apply the changes (the "Accept" button).
Create a cross-connect profile for the Internet service for NTU-SFP-200 according to the example below. Apply the changes ("Accept" button).
Create a cross-connect profile for the management service (management of the switch into which NTU-SFP is plugged) according to the example below. Apply the changes ("Accept" button).
Configuring cross-connect for NTU-RG
Create an IPTV service cross-connect profile for NTU-RG according to the example below. Apply the changes (click "Accept").
Create an Internet service cross-connect profile for NTU-RG according to the example below. Apply the changes (click "Accept").
Create a VoIP service cross-connect profile for NTU-RG according to the example below. Apply the changes (click "Accept").
Create a cross-connect profile for the service of ONT interaction with the built-in ACS server of the OLT for NTU-RG according to the example below. Apply the changes (click "Accept").
Configuring ports profiles
To configure port profiles, select the desired OLT in the device tree, then go to the “Configuration” tab in the settings field, then to the ‘Profiles’ section and select the “PortsProfile” type. Default profiles of all types are always created on the OLT. The default profile for ports is ports1. To add a new profile, use the button. The configuration tab for this section looks like this:
Configuring ports for NTU-1
Create a ports profile for NTU-1 according to the example below. Of all the available settings, only the following sections are affected: Multicast dynamic entry 1 and UNI #1. Apply the changes (click the "Accept" button).
Configuring ports for NTU-SFP
Create a ports profile for NTU-SFP according to the example below. Of all the available settings, only the following sections are affected: Multicast dynamic entry 1 and UNI #1. Apply the changes (click the "Accept" button).
Configuring ports for NTU-RG
Create a ports profile for NTU-RG according to the example below. Of all the available settings, only the following sections are affected: Multicast dynamic entry 1 and VEIP. Apply the changes (click "Accept").
Configuring VLAN
VLAN configuration is performed in the "VLAN" section of the "Configuration" tab. All VLANs on the OLT are created by default, but are not present in the EMS list, as they are present in the default configuration, which is hidden. To add the required VLAN to the interface, you can create it in the EMS GUI. By default, the VLAN section configuration tab looks like this:
To add a VLAN click the icon. Create VLAN multicast with VLAN ID 30.
The VLAN editing window will open automatically. Here individual multicast processing parameters for the VLAN being created, as well as VLAN name in the configuration can be specified. When creating a VLAN, it is possible to leave all parameters at their default values. As an example, specify the name "IPTV" for the VLAN.
VLAN configuration on OLT uplink interfaces is performed on the Front-port tab. To edit VLANs assigned to the interface, select the desired Front-port from the list, then click the "Edit" button.
The following parameters can be specified in the Uplink interface settings window:
- Interface description.
- SwitchPort mode – VLAN operating mode on the port. Available options are general, access, and trunk. General is used by default.
- VLAN Allow – list of VLANs allowed on the interface. The items on the list are separated by commas.
- Bridge Allow – list of VLANs for which bridging (traffic transfer between neighboring Front ports) is allowed. If there are several VLANs, they are separated by commas.
- PVid – VLAN ID to which untagged traffic arriving at the port will be assigned (VLAN 1 by default).
Perform the same steps to create a VLAN and add it to the Front-port configuration for Internet, Management, and Telephony services.
Configuring multicast on OLT
Multicast processing on OLT is configured in the "Multicast" section of the "Configuration" tab. In the current implementation, only global IGMP snooping management is available in this section. The parameter must be enabled.
The igmp proxy report settings required by the diagram can only be configured in CLI.
LTP-16N# configure terminal LTP-16N(configure)# ip igmp snooping enable LTP-16N(configure)# ip igmp proxy report enableLTP-16N(configure)# ip igmp proxy report range 224.0.0.1 239.255.255.254 from 2149 to 30 LTP-16N(configure)# do commitLTP-16N(configure)# do save
Configuring the built-in ACS server
Addressing and VLAN settings for the built-in ACS server must not overlap with the settings of other OLT interfaces: management, port-oob, other L3 interfaces.
The built-in ACS server configuration required by the diagram can only be performed in CLI.
LTP-16N(configure)# ip acs LTP-16N(config)(acs)# acs-server enable LTP-16N(config)(acs)# acs-server ip 192.168.200.1 LTP-16N(config)(acs)# acs-server mask 255.255.248.0 LTP-16N(config)(acs)# acs-server vlan 4094 LTP-16N(config)(acs)# acs-server login acs LTP-16N(config)(acs)# acs-server password acsacs LTP-16N(config)(acs)# dhcp-server enable LTP-16N(config)(acs)# dhcp-server range 192.168.200.10 192.168.207.250 LTP-16N(config)(acs)# dhcp-server option-43 enable LTP-16N(config)(acs)# exit
Configuring the management service profile
To configure the management profile, select the desired OLT in the device tree, then go to the "Configuration" tab in the settings field, then to the "Profiles" section and select the "ManagementProfile" type. Default profiles of all types are already created on the OLT. The default profile for management is management1. To add a new profile, use the button. The configuration field for this section looks like this:
Create a cross-connect profile for the service of ONT interaction with the built-in ACS server of the OLT according to the image below. Apply the changes (click "Accept").
Registering ONT on OLT and assigning configuration to ONT
ONT and their configurations are managed in the "ONT List" tab. This list displays registered and unregistered ONT. The screenshot below shows an example of this section when there are connected but unregistered ONT.
ONT registration and configuration assignment can be performed by double-clicking on the ONT in the list. This will open a window where you need to assign an ID in the configuration and the necessary service profiles to the ONT. The "Serial" and "PON Port ID" fields will be filled in automatically based on the actual PON serial number and the physical number of the PON port to which the ONT is connected. The "ONT ID" field will also be filled in automatically based on the next available ONT ID. These values can be adjusted manually. After entering the necessary information in the current window, click "Accept" and then click "Apply" on the control panel.
NTU-1 registration
Register and apply configuration profiles for NTU-1 as shown in the example below.
NTU-RG Registration
Register and apply configuration profiles for NTU-RG-5520G-Wax and NTU-RG-541G-Wac as shown in the example below.
NTU-RG-5520G-Wax
NTU-RG-5421G-Wac
NTU-SFP-200 registration
Register and apply configuration profiles for NTU-SFP-200 as shown in the example below.
Verification
After applying the settings, if the ONT is successfully registered, the status will change to "OK" and the indicator color will change to green.