Wireless access point
WEP-2ac, WEP-2ac Smart
User manual,  
Firmware version 1.16.0 (02.2019)  

IP address:  http://192.168.1.10
User Name: admin
Password: password

<div class="aui-message error aui-message-error">
<p class="title">
<span class="aui-icon icon-error"></span>
<strong>Comala Metadata License Details</strong>
</p>
<p>Invalid commercial evaluation license with a expired error. Please click <a href="https://marketplace.atlassian.com/plugins/org.andya.confluence.plugins.metadata" target="_blank">here</a> to purchase a commercial license.</p>
</div>

Introduction

Modern tendencies of telecommunication development necessitate operators to search for the most optimal technologies, allowing you to satisfy drastically growing needs of subscribers, maintaining at the same time consistency of business processes, development flexibility and reduction of costs of various services provision. Wireless technologies are spinning up more and more and have paced a huge way for a short time from unstable low-speed communication networks of low radius to broadband networks equitable to speed of wired networks with high criteria for the quality of provided services.

WEP-2ac and WEP-2ac Smart are Wi-Fi access points of the Enterprise class. The devices are dedicated to be installed inside buildings as access points and to create a seamless wireless network using several identical access points on a large area.
This manual specifies intended purpose, main technical parameters, design, installation procedure, safe operation rules and installation recommendations for WEP-2ac and WEP-2ac Smart wireless access points.

Symbols

Notes and warnings

Notes contain important information, tips or recommendations on the device operation and setup.

Warnings are used to inform the user about harmful situations for the device and the user alike, which could cause malfunction or data loss.

Device Description

Purpose

WEP-2ac and WEP-2ac Smart wireless access points (hereinafter the devices) are designed to provide users with access to a high-speed and safe network.

The devices are dedicated to create L2 wireless networks interfacing with a wired network. WEP-2ac and WEP-2ac Smart are connected to a wired network via 10/100/1000M Ethernet interface and arrange high-speed access to the Internet for devices supporting Wi-Fi technology at 2.4 and 5 GHz. The devices have two radio interfaces to organize two physical wireless networks.

WEP-2ac and WEP-2ac Smart support high requirement to the quality and allows transmitting more important traffic in more priority queue. Prioritization is provided due to QoS main technologies: CoS (tags in VLAN packet fields) and ToS (tags in IP packets). Besides the standard methods of prioritization, the devices allow you to assign demands for traffic transmission almost in every packet field from MAC to TCP/UDP port. The ACL rules and shaping allow you to control access, quality of service and restrictions for all subscribers as well as for each subscriber individually.

The devices are designed to be installed in offices, state buildings, conference halls, laboratories, hotels, etc. The creation of virtual access points with different types of encryption allows clients to delimit access rights among users and groups of users.

Devices specifications

Interfaces:

  • 1 Ethernet 10/100/1000Base-T (RJ-45) port with PoE+ support;
  • Console RJ-45 .

Functions:

WLAN capabilities:

  • Support for IEEE 802.11a/b/g/n/ac standards;
  • Data aggregation including A-MPDU (Tx/Rx) and A-MSDU (Rx);
  • WMM-based packet prioritization and scheduling;
  • Dynamic frequency selection (DFS);
  • Support for Hidden SSID;
  • 32 virtual access points;
  • Third-party access point detection;
  • Workgroup bridge;
  • WDS;
  • Mesh support;
  • APSD.

Network functions:

  • Auto-negotiation of speed, duplex mode and switching between MDI and MDI-X modes;
  • Support for VLAN;
  • Authentication support 802.1X;
  • Support for 802.11r;
  • DHCP Client;
  • IPv6;
  • LLDP;
  • ACL;
  • SNMP;
  • GRE. 

Cluster operation mode:

  • Organization of a cluster with capacity of up to 64 access points;
  • Automatic synchronization of the access points configurations in a cluster;
  • Automatic firmware update for access points in a cluster;
  • Single Management IP — united address to control access points in a cluster;
  • Auto-distribution of frequency channels among access points;
  • Auto-distribution of output power among access points.

QoS functions:

  • Priority and profile-based packet scheduling;
  • Bandwidth limitation for each SSID;
  • Changing WMM parameters for each radio interface.

Security

  • E-mail notification on system events;
  • Centralized authorization via RADIUS server (WPA Enterprise);
  • WPA/WPA2;
  • Captive Portal;
  • Support for Internet Protocol Security (IPsec)

The figure below illustrates an application scheme of WEP-2ac.

 

Technical parameters of the devices

WAN Ethernet interface parameters

Number of ports

1

Connector

RJ-45

Data rate, Mbps

10/100/1000, auto-negotiation

Standards

BASE-T

Parameters of the wireless interface 

Standards

802.11a/b/g/n/ac

Frequency range, MHz

2400–2483.5 MHz, 5150–5850 MHz

Modulation

CCK, BPSK, QPSK, 16QAM, 64QAM, 256QAM

Operating channels

802.11b/g/n: 1–13 (2412–2472 MHz)
802.11a/ac: 36–64 (5180–5320 MHz), 100–144 (5500–5720 MHz),
149–165 (5745–5825 MHz)

Data rate, Mbps

6, 9, 12, 18, 24, 36, 48, 54, MCS0-MCS15, MCS0-9 NSS1, MCS0-9 NSS2
802.11n: up to 144.4 Mbps (channel 20 MHz), up to 300 Mbps (channel 40 MHz)
802.11ac: up to 866.7 Mbps (80 MHz)

Maximum output power of the transmitter
(Defined by Transmit Power Limit and Transmit Power Control)

2.4 GHz: up to 18 dBm
5 GHz: up to 21 dBm

Receiver sensitivity

2.4 GHz: up to -98 dBm; 5 GHz: up to -94 dBm

Security

Centralized authentication via RADIUS server (WPA Enterprise)
64/128/152-bit WEP encryption, WPA/WPA2
Support for Captive Portal
E-mail notification on system events

Support for 2х2 MIMO 

Two embedded Broadcom chips: BCM47452 (5 GHz, IEEE 802.11a/n/ac) and BCM43217 (2.4 GHz, IEEE 802.11b/g/n) 

Management 

Remote management

Web interface, Telnet, SNMP, SSH, EMS management system.
Firmware update and configuration through DHCP Autoprovisioning

Access restriction

by password, by IP address

General parameters 

Processor

Broadcom BCM47452

NAND

128 MB NAND Flash

RAM

256 MB RAM DDR3

Power supply

PoE+ - 48V/54V (IEEE 802.3at-2009).

Power consumption

no more than 13 W

Operating temperature

from +5 to +40°С

Operating humidity at 25°С

up to 80%

Dimensions of WEP-2ac

200х40 mm

Dimensions of WEP-2ac Smart 200х43 mm

Weight

no more than 0.4 kg

Design

WEP-2ac, WEP-2ac Smart are housed in a plastic case.

Main panel of the devices

The figure below shows a layout of WEP-2ac and WEP-2ac Smart main panel:

The following light indicators, connectors and controls are located on the main panel of WEP-2ac, WEP-2ac Smart:

Main panel element 

Description

1

Link/Speed

Light indication of GE port (PoE)

2

GE (PoE)

GE port for power supply through PoE+

3

Console

Console port RS-232 for local management

4

F

Functional key

5

Wi-Fi

Indicators of Wi-Fi modules activity

Light indication

The Wi-Fi, LAN and power indicators show the device current state. The table below lists possible status of the LEDs.

LED

LED state

Device state

Wi-Fi (5)

 

green LED glows constantly

Wi-Fi is enabled

green flashes

The process of data transmission trough a wireless network

LAN (1)

 

green LED (10, 100 Mbps)/ orange LED (1000 Mbps)

the link with the connected network device is established

green LED flashes

the process of packet data transmission through LAN interface

Power (located on the front panel)

 

 

green LED glows constantly

the device power supply is enabled, normal operation, IP address is obtained

orange LED glows constantly

the device is loaded but IP address is not received via DHCP

red LED glows constantly

the device is loading

Factory reset

In order to reset the device to factory settings, press and hold the 'F' button until «Power» indicator flashes. The device is rebooted automatically. DHCP client is launched by default.

If the address is not received via DHCP, the device will have IP address – 192.168.1.10 and subnet mask – 255.255.255.0. User Name and Password to access via Web interface: admin/password.

Delivery package

The delivery package includes:

  • Wireless access point WEP-2ac/WEP-2ac Smart;
  • Mounting kit;
  • User manual (supplied on a CD);
  • Conformity certificate;
  • Technical passport.

Installation rules

This section defines safety rules, installation recommendations, setup procedure and the device starting procedure.

Safety rules

  1. Do not install the device near heat sources and in rooms with environment temperature below 5°С or higher 40°С.
  2. Do not use the device in room with high level of humidity. Do not expose the device to smoke, dust, water, mechanical vibrations or shocks.
  3. Do not open the case of the device. There are no user serviceable parts inside.

    Do not cover ventilation holes and do not put other objects on the device in order to prevent overheating of device components.

Installation recommendations

  1. Recommended location for device installation: horizontal, on a ceiling.
  2. Before you install and enable the device, check the device for visible mechanical defects. If defects are observed you should stop the device installation, draw up corresponding act and contact the supplier.
  3. If the device has been exposed for a long time at a low temperature, it must be left to stand for two hours at room temperature before use. After a long stay of the device in conditions of high humidity, let it stand under normal conditions for at least 12 hours before switching on.
  4. During the device installation to provide Wi-Fi coverage area with the best characteristics take into account the following rules:
    1. Install the device at the center of the wireless network;
    2. Minimize the number of obstacles (walls, roof, furniture, etc.) between WEP-2ac/WEP-2ac Smart and other wireless network devices;
    3. Do not install the device near (about 2 m) electrical and radio devices;
    4. It is not recommended to use radiophone and other equipment operating at the frequency of 2.4 GHz, 5 GHz in Wi-Fi effective radius;
    5. Obstacles in the form of glass/metal constructions, brick/concrete walls, water cans and mirrors can significantly reduce Wi-Fi action radius. It is not recommended to place the device inside a false ceiling as metal frame causes multipath signal propagation and signal attenuation.
  5. In case of the installation of several access points, cell action radius must overlap with action radius of a neighboring cell at level of -65 ÷ -70 dBm. Decreasing of the signal level on cells borders to -75 dBm is permitted if it does not involve the use of VoIP, streaming video and other traffic that is sensitive to losses in a wireless network.

Calculating the required number of access points

To calculate the required number of access points, you need to evaluate the required coverage zone. For a more accurate assessment, it is necessary to make a radio examination of the room. Approximate radius of coverage area of WEP-2ac with a good-quality signal in case of mounting on a ceiling in typical office: 40-50 m at 2.4 GHz and 20-30 m at 5 GHz. In case of no obstacles, the radius of the coverage area is up to 100 m at 2.4 GHz and up to 60 m at 5 GHz. 

The table below describes rough attenuation values.

Material

Change of signal level, dB 

2.4 GHz

5 GHz

Organic glass

-0.3

-0.9

Brick

-4.5

-14.6

Glass

-0.5

-1.7

Plaster slab

-0.5

-0.8

Wood laminated plastic

-1.6

-1.9

Plywood

-1.9

-1.8

Plaster with wirecloth

-14.8

-13.2

Breezeblock

-7

-11

Metal lattice (mesh 13*6mm, metal 2mm)

-21

-13

Channel selection for neighboring access points

  • It is recommended to set non-overlapping channels to avoid interchannel interference between neighboring access points. 


General diagram of frequency channel closure in the range of 2.4 GHz


  • The example of channel allocation scheme among neighboring access points in the frequency range of 2.4 GHz when channel width is 20 МHz:


Scheme of channel allocation among neighboring access points in the frequency range of 2.4 GHz when channel width is 20 MHz

  • It is recommended to save the same allocation scheme between floors, see the figure below: 



Scheme of channel allocation between neighboring access points that are located on different floors

  • When the width of used channel is 40 MHz, there is no non-overlapping channels in the frequency range of 2.4 GHz. In such cases, you should select channels maximally separated from each other:



Channels used in a range of 5GHz when channel width is 20, 40 or 80 MHz

WEP-2ac, WEP-2ac Smart installation

The devices can be installed on plain surface (wall, ceiling) according to safety rules and recommendations mentioned above.

The device delivery package includes required mounting kit to attach the device to plain surface.

Wall mounting

  1. Fix the bracket (included in the delivery package) to the wall:

Attaching the bracket to a wall

    1. The figure shows the bracket allocation.
    2. Pass the wires into the corresponding grooves on the bracket while installing the bracket.
    3. Align together three bolt holes on bracket and bolt holes on the wall. Screw the brackets to the wall by using a screwdriver.
  1. Install the device

Device installation (front view)

    1. Connect cables to the corresponding device connectors, the description of the device connectors is represented in section Design.
    2. Align the device and bracket together, fix the position, turning clockwise.

Mounting to a false ceiling

It is not recommended to place the device inside a false ceiling as metal frame causes multipath signal propagation and signal attenuation.

1 – metal bracket;
2 – armstrong panel;
3 – plastic bracket;
4 – device.
  1. Fix metal and plastic bracket to a ceiling.
  2. Plastic bracket (3) should be join to a metal one (1) on a false ceiling in the following order: metal bracket -> armstrong panel -> plastic bracket.
  3. Cut the hole in the armstrong panel. The size of the hole should be equal to hole of metal bracket. Conduct wires through the hole.
  4. Align holes in metal bracket with holes of armstrong panel and plastic bracket. Screw the brackets by using a screwdriver.
  5. Install the device.
    1. Connect cables to the corresponding device connectors, the description of the device connectors is represented in section Design.
    2. Align the device and bracket together, fix the position, turning the device clockwise.

Removing the device from the bracket

For removing the device from the bracket:

  1. Turn the device counter-clockwise.
  2. Remove the device.

Application A. Anntenna patterns of WEP-2ас and WEP-2ac Smart

2.4 GHz range


5 GHz range


Application B. Connectors pin array

RJ-45 pin array
The following scheme is used in case of connection via twisted-pair wire.

Side А:

  1. white-orange;
  2. orange;
  3. white-green;
  4. blue;
  5. white-blue;
  6. green;
  7. white-brown;
  8. brown.

Console cable RJ45-DB9 pin array

Serial Port (RJ-45 Connector) Pin

Adapter (DB-9) Pin

3 (TXD)

2 (RXD)

4 (Signaling Ground)

5 (Signaling Ground)

5 (Signaling Ground)

5 (Signaling Ground)

6 (RXD)

3 (TXD)

The example of implementation is shown on the following figure: 

The list of changes

Document's versionDate of issueChanges
Version 1.912.02.2019

Synchronization with firmware version 1.16.0

Version 1.830.11.2018

Synchronization with firmware version 1.15.0

Version 1.710.08.2018

Synchronization with firmware version 1.14.0

Version 1.68.05.2018

Synchronization with firmware version 1.12.2

Changes:

  • Device description
Version 1.526.12.2017Synchronization with firmware version 1.11.4
Version 1.430.10.2017Synchronization with firmware version 1.11.2
Version 1.302.08.2017Synchronization with firmware version 1.10.0
Version 1.201.02.2017Synchronization with firmware version 1.9.0
Version 1.1
16.12.2016Synchronization with firmware version 1.8.0
Version 1.020.07.2016First edition
Firmware version 1.16.0

TECHNICAL SUPPORT

Contact Eltex Service Center to receive technical support regarding our products:
29v Okruzhnaya Street, Novosibirsk, Russian Federation, 630020.
Technical support phone numbers:
+7(383) 274-47-87,
+7(383) 272-83-31,
E-mail: techsupp@eltex.nsk.ru
Visit Eltex official website to get the relevant technical documentation and software, benefit from our knowledge base, send us online request or consult a Service Centre Specialist in our technical forum.
Eltex official website: http://eltex-co.ru
Technical forum: http://eltex-co.ru/forum
Knowledge base: *http://eltex-co.ru/support/knowledge*
Download center: *http://eltex-co.ru/support/downloads*

  • Нет меток