Для этого необходимо воспользоваться командой:
show fiber-ports optical-
...
transceiver detailed interface {
...
gigabitethernet gi_port | tengigabitethernet te_port}
...
Пример
...
show fiber-ports optical-transceiver detailed interface
...
TengigabitEthernet 0/
...
Port Temp Voltage Current Output Input LOS Transceiver
...
1
Port Temp Voltage Current Output Input LOS Transceiver
[C]
...
[V]
...
[mA]
...
Power
...
Power Type
...
[mW / dBm]
...
[mW / dBm]
...
----------- ------ ------- -------- ------------- -------------- ---- -------------
...
te1/0/
...
1 35 3.
...
37 15.
...
78 0.
...
25 / -6.
...
00 0.
...
20 / -
...
6.
...
79 N/
...
S Fiber
...
Temp - Internally measured transceiver temperature
...
Voltage - Internally measured supply voltage
...
Current - Measured TX bias current
Output
...
Power - Measured TX output power in milliWatts/dBm
Input
...
Power - Measured RX received power in milliWatts/dBm
...
LOS - Loss of signal
N/A - Not Available, N/S - Not Supported, W - Warning, E - Error
Transceiver information:
Vendor name:
...
OEM
Serial number:
...
S1253261240356
Part number: FH-SB5312CDL20
Vendor revision: A0
Connector type: LC
Type: SFP/SFP+
Compliance code:
...
unknown
Laser wavelength:
...
1550 nm
Transfer distance: 20000 m
Diagnostic: supported
Примечание: на коммутаторах 23хх, 33хх и т.д. с версией 4.0.х команда имеет вид
show fiber-ports optical-transceiver interface {gigabitethernet gi_port | tengigabitethernet te_port}
Threshold parameters:
Temperature [C]
Low Warning: -35 High Warning: 95
Low Alarm: -40 High Alarm: 100
Voltage [V]
Low Warning: 2.90 High Warning: 3.50
Low Alarm: 2.80 High Alarm: 3.60
Current [mA]
Low Warning: 2.00 High Warning: 70.00
Low Alarm: 1.00 High Alarm: 80.00
Output Power [mW / dBm]
Low Warning: 0.12 / -9.00 High Warning: 0.50 / -3.00
Low Alarm: 0.10 / -10.00 High Alarm: 0.63 / -2.00
Input Power [mW / dBm]
Low Warning: 0.00 / -23.98 High Warning: 1.00 / 0.00
Low Alarm: 0.00 / -26.99 High Alarm: 1.99 / 3.00