The system log management commands are described in this section. In a system operating with central switch redundancy, commands from this section can only be entered and executed on the master module.

clear alarm

This command is used to delete entries from the system alarm log.

Syntax     

clear alarm <TYPE>

Parameters

<TYPE> – log entry type for deletion:

  • active – active alarms deletion;
  • before – deleting all log entries (alarm events) before the specified date. The date is specified in format of YYYY.MM.DD-hh:mm;
  • events – delete all event log entries.

Command mode

ROOT

Example

ma4000# clear alarm active

The log entries about active accidents have been deleted.

show alarm

This command will show the alarm list.

Time – alarm registration time, DD:MM:YYYY hh:mm:ss;

Priority – alarm priority;

Text – alarm description.

Syntax     

show alarm <PARAM> [ALARM]

Parameters

<PARAM> – alarm type:

  • active – show active alarm list;
  • events – show all event log;
  • configuration – show configuration of selected alarm.

Command mode

ROOT

Example

ma4000(alarms)#show alarm active
   Active alarms
   ~~~~~~~~~~~~~
Time                       Priority   Text                                                 
------------------------   ------   ----------------------------------------   
06-09-2011 14:02:36        2        MA4000_ALARM_LINK_DOWN front-port 1/1                
06-09-2011 14:02:36        2        MA4000_ALARM_LINK_DOWN front-port 1/2  

journal filter

This command sets the rules of making entries for some events in the log.

The use of a negative form (no) of the command sets the default value.

Syntax     

[no] journal filter<FILTER>

Parameters

<FILTER> – filter events by type:

dying-gasp – set local database to disable the sending of ONT dying gasp alarm messages;

ont-state – set local database to cancel sending alarm messages to the log when the ONT status changes: blocked, ok, free.

Command mode

CONFIG

Example

ma4000(config)# journal filter ont-state

journal keep-time

This command sets the maximum time for storing entries in the event log.

The use of a negative form (no) of the command sets the default value.

Syntax     

journal keep-time <TIME>

Parameters

<TIME> – time period, may take values in the range [10..10000], in hours.

Command mode

CONFIG

Example

ma4000(config)#journal keep-time 20

journal max-size

This command is used to set the size of the system log.

The use of a negative form (no) of the command sets the default value.

Syntax     

journal max-size <SIZE>

Parameters

<SIZE> – maximum log size, may take values in the range [1000..50000] Kbyte.

Command mode

CONFIG

Example

ma4000(config)# journal max-size 10000

show alarm events

This command is used to view the event log entries.

Syntax     

show alarm events

Parameters

The command contains no arguments.

Command mode

ROOT

Example

ma4000# show alarm events 

   Alarms
   ~~~~~~
                           Priori                                                        
Time                       ty       Text                                                 
------------------------   ------   ---------------------------------------------   
27-11-2014 16:42:05        2        PLC, slot 6: ELTX5F0002A0 2 20 FREE 'NTU-2V'         
                                    '3.50.2.1193'                                        

27-11-2014 16:44:41        2        PLC, slot 6: ELTX5F0002A0 2 20 OK 'NTU-2V'           
'3.50.2.1193'    

show alarm active

This command is used to view the active event entries.

Syntax     

show alarm active

Parameters

The command contains no arguments.

Command mode

ROOT

Example

MA4000# show alarm active 

   Active alarms
   ~~~~~~~~~~~~~
                           Priori                                                        
Time                       ty       Text                                                 
------------------------   ------   --------------------------------------------------   
28-12-2016 15:46:37        1        MA4000_ALARM_LINK_DOWN front-port 1/1                
28-12-2016 15:46:37        1        MA4000_ALARM_LINK_DOWN front-port 1/2    

2 active alarms   

alarm fan

This command allows to configure the event generation parameters for logging the fan operation status.

The use of a negative form (no) of the command sets the default configuration.

Syntax     

alarm fan <PARAM> <VALUE>
no alarm fan <PARAM>

Parameters

<PARAM> – event parameter:

  • max-rpm – set the upper limit of fan speed rpm;
  • min-rpm – set the lower limit of fan speed rpm;
  • in – formation of the event when the parameter value goes abroad;
  • out – formation of event normalization when the parameter value is returned to the boundaries;
  • severity – describes the degree of importance of the event: info, minor, major, critical;
  • ttl – time an event exists in the active alarms log. (from 1 to 2,147,483,647). Specified in seconds. It has several special values.
  • 0 – event is in the log until the normalizing event comes;
  • 1 – SNMP trap is sent if specified, but the event is not logged in the alarm log.

<VALUE> – parameter value, optional parameter.

Command mode

CONFIG

Example

ma4000(config)# alarm fan max-rpm 2000

alarm free-space

This command allows to configure the event generation parameters for recording to the alarm log if there is not enough free disk space.

The use of a negative form (no) of the command sets the default configuration.

Syntax     

alarm free-space <PARAM> <VALUE>
no alarm free-space <PARAM>

Parameters

<PARAM> – event parameter, may take values:

  • level – set the lower limit of free disk space, in %;
  • in – formation of the event when the parameter value goes abroad;
  • out – formation of event normalization when the parameter value is returned to the boundaries;
  • severity – describes the degree of importance of the event (info, minor, major, critical);
  • ttl – time an event exists in the active alarms log. (from 1 to 2,147,483,647). Specified in seconds. It has following special values:
    • 0 – event is in the log until the normalizing event comes;
    • 1 – SNMP trap is sent if specified, but the event is not logged in the alarm log.

<VALUE> –  parameter value.

Command mode

CONFIG

Example

ma4000(config)# alarm free-space level 20

alarm load-average

This command allows to configure the event generation parameters for logging the alarms at high CPU load.

The use of a negative form (no) of the command sets the default configuration.

Syntax     

alarm load-average <PARAM> <VALUE>
no alarm load-average <PARAM>

Parameters

<PARAM> – event parameter, may take values:

  • level – set upper CPU load level;
  • in – formation of the event when the parameter value goes abroad;
  • out – formation of event normalization when the parameter value is returned to the boundaries;
  • severity – describes the degree of importance of the event (info, minor, major, critical);
  • ttl – time an event exists in the active alarms log. (from 1 to 2,147,483,647). Specified in seconds. It has several special values:
    • 0 – event is in the log until the normalizing event comes;
    • 1 – SNMP trap is sent if specified, but the event is not logged in the alarm log.

<VALUE> – parameter value.

Command mode

CONFIG

Example

ma4000(config)# alarm load-average level 255

alarm ont-high-rx-power

This command allows to configure the event generation parameters for logging alarms when the received signal level on the ONT side is above a threshold value.

The use of a negative form (no) of the command sets the default configuration.

Syntax     

alarm ont-high-rx-power <PARAM> <VALUE>
no alarm ont-high-rx-power <PARAM>

Parameters

<PARAM> – event parameter, may take values:

  • level – sets the maximum power level of the signal received by ONT (-127..0) dBm, special value 0xFF (disables sending no alarm ont-high-rx-power level);
  • in – formation of the event when the parameter value goes abroad;
  • out – formation of event normalization when the parameter value is returned to the boundaries;
  • severity – describes the degree of importance of the event (info, minor, major, critical);
  • ttl – time an event exists in the active alarms log. (from 1 to 2,147,483,647). Specified in seconds. It has several special values:
    • 0 – event is in the log until the normalizing event comes;
    • 1 – SNMP trap is sent if specified, but the event is not logged in the alarm log.

<VALUE> – parameter value.

Command mode

CONFIG

Example

ma4000(config)# alarm ont-high-rx-power level -12

alarm ont-low-rx-power

This command allows to configure the event generation parameters for logging alarms when the received signal level on the ONT side is below a threshold value.

The use of a negative form (no) of the command sets the default configuration.

Syntax     

alarm ont-low-rx-power <PARAM> <VALUE>
alarm low-rx-power <PARAM> <VALUE>
no alarm ont-low-rx-power <PARAM>
no alarm low-rx-power <PARAM>

Parameters

<PARAM> – event parameter, may take values:

  • level – sets the minimum power level of the signal received by ONT (-127..0) dBm, special value 0xFF (disables sending no alarm ont-low-rx-power level);
  • in – formation of the event when the parameter value goes abroad;
  • out – formation of event normalization when the parameter value is returned to the boundaries;
  • severity – describes the degree of importance of the event (info, minor, major, critical);
  • ttl – time an event exists in the active alarms log. (from 1 to 2,147,483,647). Specified in seconds. It has following special values:
    • 0 – event is in the log until the normalizing event comes;
    • 1 – SNMP trap is sent if specified, but the event is not logged in the alarm log.

<VALUE> – parameter value.

Command mode

CONFIG

Example

ma4000(config)# alarm ont-low-rx-power level -28 

ram

This command allows to configure the event generation parameters for logging alarms when the free RAM amount of the device is below the threshold value.

The use of a negative form (no) of the command sets the default configuration.

Syntax     

alarm ram <PARAM> <VALUE>
no alarm ram <PARAM>

Parameters

<PARAM> – event parameter, may take values:

  • free-ram – set the threshold value of the minimum free memory capacity in %;
  • in – formation of the event when the parameter value goes abroad;
  • out – formation of event normalization when the parameter value is returned to the boundaries;
  • severity – describes the degree of importance of the event (info, minor, major, critical);
  • ttl – time an event exists in the active alarms log. (from 1 to 2,147,483,647). Specified in seconds. It has following special values:
    • 0 – event is in the log until the normalizing event comes;
    • 1 – SNMP trap is sent if specified, but the event is not logged in the alarm log.

<VALUE> – parameter value.

Command mode

CONFIG

Example

ma4000(config)# alarm ram free-ram 35

alarm temperature

This command allows to configure the event generation parameters for recording to the alarm log when the temperature at one of the sensors exceeds the threshold value.

The use of a negative form (no) of the command sets the default configuration.

Syntax     

alarm temperature <PARAM> <VALUE>
no alarm temperature <PARAM>

Parameters

<PARAM> – event parameter, may take values:

  • sensor1 – set the threshold value of maximum temperature at sensor 1 of PLC board, in °C;
  • sensor2 – set the threshold value of maximum temperature at sensor 2 of PLC board, in °C;
  • in – formation of the event when the parameter value goes abroad;
  • out – formation of event normalization when the parameter value is returned to the boundaries;
  • severity – describes the degree of importance of the event (info, minor, major, critical);
  • ttl – time an event exists in the active alarms log. (from 1 to 2,147,483,647). Specified in seconds. It has following special values:
    • 0 – event is in the log until the normalizing event comes;
    • 1 – SNMP trap is sent if specified, but the event is not logged in the alarm log.

<VALUE> – parameter value.

Command mode

CONFIG

Example

ma4000(config)# alarm temperature sensor1 66

alarm login

This command allows to configure the event generation parameters for logging alarms when a user attempts to connect to the system (ssh/telnet/console).

The use of a negative form (no) of the command sets the default configuration.

Syntax     

alarm login [<PARAM> <VALUE>]
no alarm login <PARAM>

Parameters

<PARAM> – event parameter, may take values:

  • in – formation of the event when an accident occurs;
  • out – formation of event normalization at normalization of the accident;
  • severity – describes the degree of importance of the event (info, minor, major, critical);
  • ttl – time an event exists in the active alarms log. (from 1 to 2,147,483,647). Specified in seconds. It has following special values:
    • 0 – event is in the log until the normalizing event comes;
    • 1 – SNMP trap is sent if specified, but the event is not logged in the alarm log.

<VALUE> – parameter value.

Command mode

CONFIG

Example

ma4000(config)# alarm login severity info

alarm config-save

This command allows to configure the event generation parameters for logging alarms while saving the device configuration.

The use of a negative form (no) of the command sets the default configuration.

Syntax     

alarm config-save <PARAM> <VALUE>
no alarm config-save <PARAM>

Parameters

<PARAM> – event parameter, may take values:

  • in – formation of the event when an accident occurs;
  • out – formation of event normalization at normalization of the accident;
  • severity – describes the degree of importance of the event (info, minor, major, critical);
  • ttl – time an event exists in the active alarms log. (from 1 to 2,147,483,647). Specified in seconds. It has following special values:
    • 0 – event is in the log until the normalizing event comes;
    • 1 – SNMP trap is sent if specified, but the event is not logged in the alarm log.

<VALUE> – parameter value.

Command mode

CONFIG

Example

ma4000(config)# alarm config-save severity info

alarm firmware-update

This command allows to configure the event generation parameters for logging alarms while updating the device firmware.

The use of a negative form (no) of the command sets the default configuration.

Syntax     

alarm firmware-update <PARAM> <VALUE>
no alarm firmware-update <PARAM>

Parameters

<PARAM> – event parameter, may take values:

  • in – formation of the event when an accident occurs;
  • out – formation of event normalization at normalization of the accident;
  • severity – describes the degree of importance of the event (info, minor, major, critical);
  • ttl – time an event exists in the active alarms log. (from 1 to 2,147,483,647). Specified in seconds. It has following special values:
    • 0 – event is in the log until the normalizing event comes;
    • 1 – SNMP trap is sent if specified, but the event is not logged in the alarm log.

<VALUE> – parameter value.

Command mode

CONFIG

Example

ma4000(config)# alarm firmware-update severity critical

alarm duplicate-mac

This command allows to configure the event generation parameters for logging alarms when the same MAC address is detected within the same VLAN on two different ports of the device.

The use of a negative form (no) of the command sets the default configuration.

Syntax     

alarm duplicate-mac <PARAM> <VALUE>
no alarm duplicate-mac <PARAM>

Parameters

<PARAM> – event parameter:

  • in – formation of the event when an accident occurs;
  • out – formation of event normalization at normalization of the accident;
  • severity – describes the degree of importance of the event (info, minor, major, critical);
  • ttl – time an event exists in the active alarms log. (from 1 to 2,147,483,647). Specified in seconds. It has following special values:
    • 0 – event is in the log until the normalizing event comes;
    • 1 – SNMP trap is sent if specified, but the event is not logged in the alarm log.

<VALUE> – parameter value.

Command mode

CONFIG

Example

ma4000(config)# alarm duplicate-mac severity critical

alarm physical-layer-flapping

This command allows to configure the event generation parameters for logging alarms when the physical state (up/down) of the Ethernet port is changed frequently – flapping.

The use of a negative form (no) of the command sets the default configuration.

Syntax     

alarm physical-layer-flapping [<PARAM> <VALUE>]
no alarm physical-layer-flapping <PARAM>

Parameters

<PARAM> – event parameter, may take values:

  • in – formation of the event when an accident occurs;
  • out – formation of event normalization at normalization of the accident;
  • severity – describes the degree of importance of the event (info, minor, major, critical);
  • ttl – time an event exists in the active alarms log. (from 1 to 2,147,483,647). Specified in seconds. It has following special values:
    • 0 – event is in the log until the normalizing event comes;
    • 1 – SNMP trap is sent if specified, but the event is not logged in the alarm log.

<VALUE> – parameter value.

Command mode

CONFIG

Example

ma4000(config)# alarm physical-layer-flapping severity critical

alarm pon-channel-no-ont

This command allows to configure the event generation parameters for logging alarms when the last (first) ONT registered on the PON port is disabled.

The use of a negative form (no) of the command sets the default configuration.

Syntax     

alarm pon-channel-no-ont <PARAM> <VALUE>
no alarm pon-channel-no-ont <PARAM>

Parameters

<PARAM> – event parameter, may take values:

  • in – formation of the event when an accident occurs;
  • out – formation of event normalization at normalization of the accident;
  • severity – describes the degree of importance of the event (info, minor, major, critical);
  • ttl – time an event exists in the active alarms log. (from 1 to 2,147,483,647). Specified in seconds. It has following special values:
    • 0 – event is in the log until the normalizing event comes;
    • 1 – SNMP trap is sent if specified, but the event is not logged in the alarm log.

<VALUE> – parameter value.

Command mode

CONFIG

Example

ma4000(config)# alarm pon-channel-no-ont severity info

alarm ont-physical-layer

This command allows to configure the event generation parameters for logging alarms when connecting/disconnecting ONT to OLT.

The use of a negative form (no) of the command sets the default configuration.

Syntax     

alarm ont-physical-layer <PARAM> <VALUE>
no alarm ont-physical-layer  <PARAM>

Parameters

<PARAM> – event parameter, may take values:

  • in – formation of the event when an accident occurs;
  • out – formation of event normalization at normalization of the accident;
  • severity – describes the degree of importance of the event (info, minor, major, critical);
  • ttl – time an event exists in the active alarms log. (from 1 to 2,147,483,647). Specified in seconds. It has following special values:
    • 0 – event is in the log until the normalizing event comes;
    • 1 – SNMP trap is sent if specified, but the event is not logged in the alarm log.

<VALUE> – parameter value.

Command mode

CONFIG

Example

ma4000(config)# alarm ont-physical-layer severity info

alarm olt-update

This command allows to configure the event generation parameters for logging alarms when the OLT firmware update is successful/in error.

The use of a negative form (no) of the command sets the default configuration.

Syntax     

alarm olt-update <PARAM> <VALUE>
no alarm olt-update <PARAM>

Parameters

<PARAM> – event parameter, may take values:

  • in – formation of the event when an accident occurs;
  • out – formation of event normalization at normalization of the accident;
  • severity – describes the degree of importance of the event (info, minor, major, critical);
  • ttl – time an event exists in the active alarms log. (from 1 to 2,147,483,647). Specified in seconds. It has following special values:
    • 0 – event is in the log until the normalizing event comes;
    • 1 – SNMP trap is sent if specified, but the event is not logged in the alarm log.

<VALUE> – parameter value.

Command mode

CONFIG

Example

ma4000(config)# alarm olt-update severity info

alarm ont-update

This command allows to configure the event generation parameters for logging alarms in the event of a successful/in error ONT firmware update by OMCI.

The use of a negative form (no) of the command sets the default configuration.

Syntax     

alarm ont-update [<PARAM> <VALUE>]
no alarm olt-update <PARAM>

Parameters

<PARAM> – event parameter, may take values:

  • in – formation of the event when an accident occurs;
  • out – formation of event normalization at normalization of the accident;
  • severity – describes the degree of importance of the event (info, minor, major, critical);
  • ttl – time an event exists in the active alarms log. (from 1 to 2,147,483,647). Specified in seconds. It has following special values:
    • 0 – event is in the log until the normalizing event comes;
    • 1 – SNMP trap is sent if specified, but the event is not logged in the alarm log.

<VALUE> – parameter value.

Command mode

CONFIG

Example

ma4000(config)# alarm ont-update severity info

alarm channel-flapping

This command allows to configure the event generation parameters for logging alarms when the physical state of the GPON port is changed frequently.

The use of a negative form (no) of the command sets the default configuration.

Syntax     

alarm channel-flapping <PARAM> <VALUE>
no alarm channel-flapping <PARAM>

Parameters

<PARAM> – event parameter, may take values:

  • in – formation of the event when an accident occurs;
  • out – formation of event normalization at normalization of the accident;
  • severity – describes the degree of importance of the event (info, minor, major, critical);
  • ttl – time an event exists in the active alarms log. (from 1 to 2,147,483,647). Specified in seconds. It has following special values:
    • 0 – event is in the log until the normalizing event comes;
    • 1 – SNMP trap is sent if specified, but the event is not logged in the alarm log.

<VALUE> – parameter value.

Command mode

CONFIG

Example

ma4000(config)# alarm channel-flapping severity info

alarm ont-flapping

This command allows to configure the event generation parameters for logging alarms when the physical state is changed frequently (flapping).

The use of a negative form (no) of the command sets the default configuration.

Syntax     

alarm ont-flapping [<PARAM> <VALUE>]
no alarm ont-flapping <PARAM>

Parameters

<PARAM> – event parameter, may take values:

  • in – formation of the event when an accident occurs;
  • out – formation of event normalization at normalization of the accident;
  • severity – describes the degree of importance of the event (info, minor, major, critical);
  • ttl – time an event exists in the active alarms log. (from 1 to 2,147,483,647). Specified in seconds. It has following special values:
    • 0 – event is in the log until the normalizing event comes;
    • 1 – SNMP trap is sent if specified, but the event is not logged in the alarm log.

<VALUE> – parameter value.

Command mode

CONFIG

Example

ma4000(config)# alarm ont-flapping severity info

alarm download

This command allows to configure the event generation parameters for logging alarms while uploading file to the device.

The use of a negative form (no) of the command sets the default configuration.

Syntax     

alarm download <PARAM> <VALUE>
no alarm download <PARAM>

Parameters

<PARAM> – event parameter, may take values:

  • in – formation of the event when an accident occurs;
  • out – formation of event normalization at normalization of the accident;
  • severity – describes the degree of importance of the event (info, minor, major, critical);
  • ttl – time an event exists in the active alarms log. (from 1 to 2,147,483,647). Specified in seconds. It has following special values:
    • 0 – event is in the log until the normalizing event comes;
    • 1 – SNMP trap is sent if specified, but the event is not logged in the alarm log.

<VALUE> – parameter value.

Command mode

CONFIG

Example

ma4000(config)# alarm download severity info

alarm ont-battery-power

This command allows to configure the event generation parameters for logging alarms when ONT is switched to power from a backup battery source (there must be hardware support for this mode of operation on ONT).

The use of a negative form (no) of the command sets the default configuration.

Syntax

alarm ont-battery-power <PARAM> <VALUE>
no alarm ont-battery-power <PARAM>

Parameters

<PARAM> – event parameter, may take values:

  • in – formation of the event when an accident occurs;
  • out – formation of event normalization at normalization of the accident;
  • severity – describes the degree of importance of the event (info, minor, major, critical);
  • ttl – time an event exists in the active alarms log. (from 1 to 2,147,483,647). Specified in seconds. It has following special values:
    • 0 – event is in the log until the normalizing event comes;
    • 1 – SNMP trap is sent if specified, but the event is not logged in the alarm log.

<VALUE> – parameter value.

Command mode

CONFIG

Example

ma4000(config)# alarm ont-battery-power severity info

alarm ont-battery-low

This command allows to configure event generation parameters for logging at low ONT battery backup source (there should be hardware support for this mode of operation on ONT).

The use of a negative form (no) of the command sets the default configuration.

Syntax

alarm ont-battery-low  [<PARAM> <VALUE>]
no alarm ont-battery-low  <PARAM>

Parameters

<PARAM> – event parameter, may take values:

  • in – formation of the event when an accident occurs;
  • out – formation of event normalization at normalization of the accident;
  • severity – describes the degree of importance of the event (info, minor, major, critical);
  • ttl – time an event exists in the active alarms log. (from 1 to 2,147,483,647). Specified in seconds. It has following special values:
    • 0 – event is in the log until the normalizing event comes;
    • 1 – SNMP trap is sent if specified, but the event is not logged in the alarm log.

<VALUE> – parameter value.

Command mode

CONFIG

Example

ma4000(config)# alarm ont-battery-low severity info

alarm lan-los

This command allows to configure the event generation parameters for logging alarms when changing the physical state of LAN ports to ONT.

The use of a negative form (no) of the command sets the default configuration.

Syntax     

alarm lan-los <PARAM> <VALUE>
no alarm lan-los  <PARAM>

Parameters

<PARAM> – event parameter, may take values:

  • in – formation of the event when an accident occurs;
  • out – formation of event normalization at normalization of the accident;
  • severity – describes the degree of importance of the event (info, minor, major, critical);
  • ttl – time an event exists in the active alarms log. (from 1 to 2,147,483,647). Specified in seconds. It has following special values:
    • 0 – event is in the log until the normalizing event comes;
    • 1 – SNMP trap is sent if specified, but the event is not logged in the alarm log.

<VALUE> – parameter value.

Command mode

CONFIG

Example

ma4000(config)# alarm lan-los severity info

alarm ont-config

This command allows to configure the event generation parameters for logging alarms when configuring ONT by OMCI.

The use of a negative form (no) of the command sets the default configuration.

Syntax     

alarm ont-config <PARAM> <VALUE>
no alarm ont-config <PARAM>

Parameters

<PARAM> – event parameter, may take values:

  • in – formation of the event when an accident occurs;
  • out – formation of event normalization at normalization of the accident;
  • severity – describes the degree of importance of the event (info, minor, major, critical);
  • ttl – time an event exists in the active alarms log. (from 1 to 2,147,483,647). Specified in seconds. It has following special values:
    • 0 – event is in the log until the normalizing event comes;
    • 1 – SNMP trap is sent if specified, but the event is not logged in the alarm log.

<VALUE> – parameter value.

Command mode

CONFIG

Example

ma4000(config)# alarm ont-config severity info

alarm file-delete

This command allows to configure the event generation parameters for recording to the alarm log when deleting files from the system.

The use of a negative form (no) of the command sets the default configuration.

Syntax     

alarm file-delete <PARAM> <VALUE>
no alarm file-delete <PARAM>

Parameters

<PARAM> – event parameter, may take values:

  • in – formation of the event when an accident occurs;
  • out – formation of event normalization at normalization of the accident;
  • severity – describes the degree of importance of the event (info, minor, major, critical);
  • ttl – time an event exists in the active alarms log. (from 1 to 2,147,483,647). Specified in seconds. It has following special values:
    • 0 – event is in the log until the normalizing event comes;
    • 1 – SNMP trap is sent if specified, but the event is not logged in the alarm log.

<VALUE> – parameter value.

Command mode

CONFIG

Example

ma4000(config)# alarm file-delete severity info

alarm physical-layer-errors

This command allows to configure the event generation parameters for logging alarms when errors occur on the Ethernet ports of the device.

The use of a negative form (no) of the command sets the default configuration.

Syntax     

alarm physical-layer-errors <PARAM> <VALUE>
no alarm physical-layer-errors <PARAM>

Parameters

<PARAM> – event parameter, may take values:

  • in – formation of the event when an accident occurs;
  • out – formation of event normalization at normalization of the accident;
  • severity – describes the degree of importance of the event (info, minor, major, critical);
  • ttl – time an event exists in the active alarms log. (from 1 to 2,147,483,647). Specified in seconds. It has following special values:
    • 0 – event is in the log until the normalizing event comes;
    • 1 – SNMP trap is sent if specified, but the event is not logged in the alarm log.

<VALUE> – parameter value.

Command mode

CONFIG

Example

ma4000(config)# alarm physical-layer-errors severity info

alarm physical-layer-block

This command allows to configure the event generation parameters for logging alarms when the device Ethernet port is locked.

The use of a negative form (no) of the command sets the default configuration.

Syntax     

alarm physical-layer-block <PARAM> <VALUE>
no alarm physical-layer-block <PARAM>

Parameters

<PARAM> – event parameter, may take values:

  • in – formation of the event when an accident occurs;
  • out – formation of event normalization at normalization of the accident;
  • severity – describes the degree of importance of the event (info, minor, major, critical);
  • ttl – time an event exists in the active alarms log. (from 1 to 2,147,483,647). Specified in seconds. It has following special values:
    • 0 – event is in the log until the normalizing event comes;
    • 1 – SNMP trap is sent if specified, but the event is not logged in the alarm log.

<VALUE> – parameter value.

Command mode

CONFIG

Example

ma4000(config)# alarm physical-layer-block severity info

This command allows to configure the event generation parameters for logging alarms when the Ethernet port state of the linkup/down device is changed.

The use of a negative form (no) of the command sets the default configuration.

Syntax     

alarm link <PARAM> <VALUE>
no alarm link <PARAM>

Parameters

<PARAM> – event parameter, may take values:

  • in – formation of the event when an accident occurs;
  • out – formation of event normalization at normalization of the accident;
  • severity – describes the degree of importance of the event (info, minor, major, critical);
  • ttl – time an event exists in the active alarms log. (from 1 to 2,147,483,647). Specified in seconds. It has following special values:
    • 0 – event is in the log until the normalizing event comes;
    • 1 – SNMP trap is sent if specified, but the event is not logged in the alarm log.

<VALUE> – parameter value.

Command mode

CONFIG

Example

ma4000(config)# alarm link severity info

alarm logout

This command allows to configure the event generation parameters for logging alarms when a user is disconnected from the CLI command interface.

The use of a negative form (no) of the command sets the default configuration.

Syntax     

alarm logout <PARAM> <VALUE>
no alarm logout <PARAM>

Parameters

<PARAM> – event parameter, may take values:

  • in – formation of the event when an accident occurs;
  • out – formation of event normalization at normalization of the accident;
  • severity – describes the degree of importance of the event (info, minor, major, critical);
  • ttl – time an event exists in the active alarms log. (from 1 to 2,147,483,647). Specified in seconds. It has following special values:
    • 0 – event is in the log until the normalizing event comes;
    • 1 – SNMP trap is sent if specified, but the event is not logged in the alarm log.

<VALUE> – parameter value.

Command mode

CONFIG

Example

ma4000(config)# alarm logout severity info

alarm ont-dying-gasp

This command allows to configure the event generation parameters for logging alarms in the event of power failure on the ONT. Support on ONT for sending PLOAM messages in case of power failure is required.

The use of a negative form (no) of the command sets the default configuration.

Syntax     

alarm ont-dying-gasp <PARAM> <VALUE>
no alarm ont-dying-gasp <PARAM>

Parameters

<PARAM> – event parameter, may take values:

  • in – formation of the event when an accident occurs;
  • out – formation of event normalization at normalization of the accident;
  • severity – describes the degree of importance of the event (info, minor, major, critical);
  • ttl – time an event exists in the active alarms log. (from 1 to 2,147,483,647). Specified in seconds. It has following special values:
    • 0 – event is in the log until the normalizing event comes;
    • 1 – SNMP trap is sent if specified, but the event is not logged in the alarm log.

<VALUE> – parameter value.

Command mode

CONFIG

Example

ma4000(config)# alarm ont-dying-gasp severity info

alarm ont-rei

This command allows to set the event generation parameters for logging alarms when receiving REI (Remote Error Indication) ERRi (BIP error of ONUi) data from ONT, see T-REC-G.984.3 11.2 Performance monitoring. Requires support on ONT.

The use of a negative form (no) of the command sets the default configuration.

Syntax     

alarm ont-rei <PARAM> <VALUE>
no alarm ont-rei  <PARAM>

Parameters

<PARAM> – event parameter, may take values:

  • in – formation of the event when an accident occurs;
  • out – formation of event normalization at normalization of the accident;
  • severity – describes the degree of importance of the event (info, minor, major, critical);
  • ttl – time an event exists in the active alarms log. (from 1 to 2,147,483,647). Specified in seconds. It has following special values:
    • 0 – event is in the log until the normalizing event comes;
    • 1 – SNMP trap is sent if specified, but the event is not logged in the alarm log.

<VALUE> – parameter value.

Command mode

CONFIG

Example

ma4000(config)# alarm ont-rei severity info

alarm ont-power-off

This command allows to configure the event generation parameters for logging alarms when the ONT PLOAM message about manual power failure is received. Requires support on ONT.

The use of a negative form (no) of the command sets the default configuration.

Syntax     

alarm ont-power-off [<PARAM> <VALUE>]
no alarm ont-power-off <PARAM>

Parameters

<PARAM> – event parameter, may take values:

  • in – formation of the event when an accident occurs;
  • out – formation of event normalization at normalization of the accident;
  • severity – describes the degree of importance of the event (info, minor, major, critical);
  • ttl – time an event exists in the active alarms log. (from 1 to 2,147,483,647). Specified in seconds. It has following special values:
    • 0 – event is in the log until the normalizing event comes;
    • 1 – SNMP trap is sent if specified, but the event is not logged in the alarm log.

<VALUE> – parameter value.

Command mode

CONFIG

Example

ma4000(config)# alarm ont-power-off severity info

alarm config-change

This command allows to configure the event generation parameters for logging alarms while changing the system configuration.

The use of a negative form (no) of the command sets the default configuration.

Syntax     

alarm config-change <PARAM> <VALUE>
no alarm config-change <PARAM>

Parameters

<PARAM> – event parameter, may take values:

  • in – formation of the event when an accident occurs;
  • out – formation of event normalization at normalization of the accident;
  • severity – describes the degree of importance of the event (info, minor, major, critical);
  • ttl – time an event exists in the active alarms log. (from 1 to 2,147,483,647). Specified in seconds. It has following special values:
    • 0 – event is in the log until the normalizing event comes;
    • 1 – SNMP trap is sent if specified, but the event is not logged in the alarm log.

<VALUE> – parameter value.

Command mode

CONFIG

Example

ma4000(config)# alarm config-change severity info

alarm shutdown

This command allows to configure the event generation parameters for logging alarms when snmpagent is restarted in the system.

The use of a negative form (no) of the command sets the default configuration.

Syntax     

alarm shutdown <PARAM> <VALUE>
no alarm shutdown <PARAM>

Parameters

<PARAM> – event parameter, may take values:

  • in – formation of the event when an accident occurs;
  • out – formation of event normalization at normalization of the accident;
  • severity – describes the degree of importance of the event (info, minor, major, critical);
  • ttl – time an event exists in the active alarms log. (from 1 to 2,147,483,647). Specified in seconds. It has following special values:
    • 0 – event is in the log until the normalizing event comes;
    • 1 – SNMP trap is sent if specified, but the event is not logged in the alarm log.

<VALUE> – parameter value.

Command mode

CONFIG

Example

ma4000(config)# alarm shutdown severity info

alarm oms

This command allows to configure the event generation parameters for logging alarms when performing the OMS-MIB operation.

This alarms signals a success or an error when performing file operations when operating over SNMP, these operations are loading and unloading the configuration backup over SNMP and firmware updates over SNMP.

The use of a negative form (no) of the command sets the default configuration.

Syntax     

alarm oms <PARAM> <VALUE>
no alarm oms <PARAM>

Parameters

<PARAM> – event parameter, may take values:

  • in – formation of the event when an accident occurs;
  • out – formation of event normalization at normalization of the accident;
  • severity – describes the degree of importance of the event: info, minor, major, critical;
  • ttl – time an event exists in the active alarms log. (from 1 to 2,147,483,647). Specified in seconds. It has following special values:
    • 0 – event is in the log until the normalizing event comes;
    • 1 – SNMP trap is sent if specified, but the event is not logged in the alarm log.

<VALUE> – parameter value.

Command mode

CONFIG

Example

ma4000(config)# alarm oms severity info

alarm ont-state-changed

This command allows to configure the event generation parameters for logging alarms at each state change (OMCI configuration) of the ONT. It is used for prompt display of ONT lists in the EMS management system.

The use of a negative form (no) of the command sets the default configuration.

Syntax     

alarm ont-state-changed <PARAM> <VALUE>
no alarm ont-state-changed <PARAM>

Parameters

<PARAM> – event parameter, may take values:

  • in – formation of the event when an accident occurs;
  • out – formation of event normalization at normalization of the accident;
  • severity – describes the degree of importance of the event: info, minor, major, critical;
  • ttl – time an event exists in the active alarms log. (from 1 to 2,147,483,647). Specified in seconds. It has following special values:
    • 0 – event is in the log until the normalizing event comes;
    • 1 – SNMP trap is sent if specified, but the event is not logged in the alarm log.

<VALUE> – parameter value.

Command mode

CONFIG

Example

ma4000(config)# alarm ont-state-changed severity info

alarm ont-config-changed

This command allows to configure the event generation parameters for logging alarms at each configuration change (OMCI configuration) of the ONT. It is used for prompt display of ONT lists in the EMS management system.

The use of a negative form (no) of the command sets the default configuration.

Syntax     

alarm ont-config-changed <PARAM> <VALUE>
no alarm ont-config-changed <PARAM>

Parameters

<PARAM> – event parameter, may take values:

  • in – formation of the event when an accident occurs;
  • out – formation of event normalization at normalization of the accident;
  • severity – describes the degree of importance of the event: info, minor, major, critical;
  • ttl – time an event exists in the active alarms log. (from 1 to 2,147,483,647). Specified in seconds. It has following special values:
    • 0 – event is in the log until the normalizing event comes;
    • 1 – SNMP trap is sent if specified, but the event is not logged in the alarm log.

<VALUE> – parameter value.

Command mode

CONFIG

Example

ma4000(config)# alarm ont-config-changed severity info

alarm channel-state-changed

This command allows to configure the event generation parameters for logging alarms at each configuration change of the GPON channel.

The use of a negative form (no) of the command sets the default configuration.

Syntax     

alarm channel-state-changed  <PARAM> <VALUE>
no alarm channel-state-changed <PARAM>

Parameters

<PARAM> – event parameter, may take values:

  • in – formation of the event when an accident occurs;
  • out – formation of event normalization at normalization of the accident;
  • severity – describes the degree of importance of the event: info, minor, major, critical;
  • ttl – time an event exists in the active alarms log. (from 1 to 2,147,483,647). Specified in seconds. It has following special values:
    • 0 – event is in the log until the normalizing event comes;
    • 1 – SNMP trap is sent if specified, but the event is not logged in the alarm log.

<VALUE> – parameter value.

Command mode

CONFIG

Example

ma4000(config)# alarm channel-state-changed severity info

alarm pon-alarm-channel

This command allows to configure the event generation parameters for logging alarms when no ONT is connected to the channel. An alarm occurs after the last ONT is disconnected and is removed after the first one is connected. It does not matter if there is ONT in the configuration or not.

The use of a negative form (no) of the command sets the default configuration.

Syntax     

alarm pon-alarm-channel <PARAM> <VALUE>
no alarm pon-alarm-channel <PARAM>

Parameters

<PARAM> – event parameter, may take values:

  • in – formation of the event when an accident occurs;
  • out – formation of event normalization at normalization of the accident;
  • severity – describes the degree of importance of the event: info, minor, major, critical;
  • ttl – time an event exists in the active alarms log. (from 1 to 2,147,483,647). Specified in seconds. It has following special values:
    • 0 – event is in the log until the normalizing event comes;
    • 1 – SNMP trap is sent if specified, but the event is not logged in the alarm log.

<VALUE> – parameter value.

Command mode

CONFIG

Example

ma4000(config)# alarm pon-alarm-channel severity info

alarm pon-alarm-onui

This command allows to configure the event generation parameters for logging alarms when an ONT emergency condition is detected.

This alarm is designed to broadcast PLOAM alarms generated on the ONT side:

LOSI: Loss of signal for ONUi

DOWI: Drift of Window of ONUi

LOFI:  Loss of frame of ONUi

RDII: Remote Defect Indication of ONUi

LOAMI: Loss of PLOAM for ONUi

LCDGI: Loss of GEM channel delineation

SDI: Signal Degraded of ONUi

SFI: Signal Fail of ONUi etc. See T-REC-G.984.3 11.1 Alarms

The use of a negative form (no) of the command sets the default configuration.

Syntax     

alarm pon-alarm-onui <PARAM><VALUE>
no alarm pon-alarm-onui <PARAM>

Parameters

<PARAM> – event parameter, may take values:

  • in – formation of the event when an accident occurs;
  • out – formation of event normalization at normalization of the accident;
  • severity – describes the degree of importance of the event: info, minor, major, critical;
  • ttl – time an event exists in the active alarms log. (from 1 to 2,147,483,647). Specified in seconds. It has following special values:
    • 0 – event is in the log until the normalizing event comes;
    • 1 – SNMP trap is sent if specified, but the event is not logged in the alarm log.

<VALUE> – parameter value.

Command mode

CONFIG

Example

ma4000(config)# alarm pon-alarm-onui severity info

alarm ont-update-inprogress

This command allows to configure the event generation parameters for logging alarms during the ONT firmware update procedure via OMCI.

The use of a negative form (no) of the command sets the default configuration.

Syntax     

alarm  ont-update-inprogress <PARAM> <VALUE>
no alarm ont-update-inprogress <PARAM>

Parameters

<PARAM> – event parameter, may take values:

  • in – formation of the event when an accident occurs;
  • out – formation of event normalization at normalization of the accident;
  • severity – describes the degree of importance of the event: info, minor, major, critical;
  • ttl – time an event exists in the active alarms log. (from 1 to 2,147,483,647). Specified in seconds. It has following special values:
    • 0 – event is in the log until the normalizing event comes;
    • 1 – SNMP trap is sent if specified, but the event is not logged in the alarm log.

<VALUE> – parameter value.

Command mode

CONFIG

Example

ma4000(config)# alarm ont-update-inprogress severity info

alarm olt-device-reset

This command allows to configure the event generation parameters for logging alarms during the PON chip reboot.

The use of a negative form (no) of the command sets the default configuration.

Syntax     

alarm  olt-device-reset <PARAM> <VALUE>
no alarm olt-device-reset <PARAM>

Parameters

<PARAM> – event parameter, may take values:

  • in – formation of the event when an accident occurs;
  • out – formation of event normalization at normalization of the accident;
  • severity – describes the degree of importance of the event: info, minor, major, critical;
  • ttl – time an event exists in the active alarms log. (from 1 to 2,147,483,647). Specified in seconds. It has following special values:
    • 0 – event is in the log until the normalizing event comes;
    • 1 – SNMP trap is sent if specified, but the event is not logged in the alarm log.

<VALUE> – parameter value.

Command mode

CONFIG

Example

ma4000(config)# alarm olt-device-reset severity info

alarm ont-signal-degrade

This command allows to configure the event generation parameters for logging alarms when detecting a low level of optical signal on the ONT side. ONT should have support for RXpower measurements and sending alarms.

The use of a negative form (no) of the command sets the default configuration.

Syntax     

alarm ont-signal-degrade <PARAM> <VALUE>
no alarm ont-signal-degrade <PARAM>

Parameters

<PARAM> – event parameter, may take values:

  • in – formation of the event when an accident occurs;
  • out – formation of event normalization at normalization of the accident;
  • severity – describes the degree of importance of the event: info, minor, major, critical;
  • ttl – time an event exists in the active alarms log. (from 1 to 2,147,483,647). Specified in seconds. It has following special values:
    • 0 – event is in the log until the normalizing event comes;
    • 1 – SNMP trap is sent if specified, but the event is not logged in the alarm log.

<VALUE> – parameter value.

Default value:

-28 dBm

Command mode

CONFIG

Example

ma4000(config)# alarm ont-signal-degrade severity info

alarm high-rx-power

This command allows to configure the event generation parameters for logging alarms when detecting a high level of optical signal on the ONT side. ONT should have support for RXpower measurements and sending alarms.

The use of a negative form (no) of the command sets the default configuration.

Syntax     

alarm high-rx-power <PARAM> <VALUE>
no alarm high-rx-power  <PARAM>

Parameters

<PARAM> – event parameter, may take values:

  • in – formation of the event when an accident occurs;
  • out – formation of event normalization at normalization of the accident;
  • severity – describes the degree of importance of the event: info, minor, major, critical;
  • ttl – time an event exists in the active alarms log. (from 1 to 2,147,483,647). Specified in seconds. It has following special values:
    • 0 – event is in the log until the normalizing event comes;
    • 1 – SNMP trap is sent if specified, but the event is not logged in the alarm log.

<VALUE> – parameter value.

Command mode

CONFIG

Default value:

-8 dBm

Example

ma4000(config)# alarm high-rx-power severity info

alarm channel-ont-count-overflow

This command allows to configure the event generation parameters for logging alarms when the number of connected ONTs on the channel exceeds the maximum allowed value – 64 ONTs.

The use of a negative form (no) of the command sets the default configuration.

Syntax     

alarm channel-ont-count-overflow  <PARAM> <VALUE>
no alarm channel-ont-count-overflow <PARAM>

Parameters

<PARAM> – event parameter, may take values:

  • in – formation of the event when an accident occurs;
  • out – formation of event normalization at normalization of the accident;
  • severity – describes the degree of importance of the event: info, minor, major, critical;
  • ttl – time an event exists in the active alarms log. (from 1 to 2,147,483,647). Specified in seconds. It has following special values:
    • 0 – event is in the log until the normalizing event comes;
    • 1 – SNMP trap is sent if specified, but the event is not logged in the alarm log.

<VALUE> – parameter value.

Command mode

CONFIG

Example

ma4000(config)# alarm channel-ont-count-overflow severity info

alarm olt-device-not-working

This command allows to configure the event generation parameters for logging alarms in case of configuration error or GPON OLT boot.

The use of a negative form (no) of the command sets the default configuration.

Syntax     

alarm olt-device-not-working <PARAM> <VALUE>
no alarm olt-device-not-working <PARAM>

Parameters

<PARAM> – event parameter, may take values:

  • in – formation of the event when an accident occurs;
  • out – formation of event normalization at normalization of the accident;
  • severity – describes the degree of importance of the event: info, minor, major, critical;
  • ttl – time an event exists in the active alarms log. (from 1 to 2,147,483,647). Specified in seconds. It has following special values:
    • 0 – event is in the log until the normalizing event comes;
    • 1 – SNMP trap is sent if specified, but the event is not logged in the alarm log.

<VALUE> – parameter value.

Command mode

CONFIG

Example

ma4000(config)# alarm olt-device-not-working severity info

alarm redundancy-switch

This command allows to configure the event generation parameters for logging alarms when switching to the GPON backup channel.

The use of a negative form (no) of the command sets the default configuration.

Syntax     

alarm redundancy-switch <PARAM> <VALUE>
no alarm redundancy-switch <PARAM>

Parameters

<PARAM> – event parameter, may take values:

  • in – formation of the event when an accident occurs;
  • out – formation of event normalization at normalization of the accident;
  • severity – describes the degree of importance of the event: info, minor, major, critical;
  • ttl – time an event exists in the active alarms log. (from 1 to 2,147,483,647). Specified in seconds. It has following special values:
    • 0 – event is in the log until the normalizing event comes;
    • 1 – SNMP trap is sent if specified, but the event is not logged in the alarm log.

<VALUE> – parameter value.

Command mode

CONFIG

Example

ma4000(config)# alarm redundancy-switch severity info

alarm redundancy-fail

This command allows to configure the event generation parameters for logging alarms during switching to the GPON backup channel by failure.

The use of a negative form (no) of the command sets the default configuration.

Syntax     

alarm redundancy-fail <PARAM> <VALUE>
no alarm redundancy-fail <PARAM>

Parameters

<PARAM> – event parameter, may take values:

  • in – formation of the event when an accident occurs;
  • out – formation of event normalization at normalization of the accident;
  • severity – describes the degree of importance of the event: info, minor, major, critical;
  • ttl – time an event exists in the active alarms log. (from 1 to 2,147,483,647). Specified in seconds. It has following special values:
    • 0 – event is in the log until the normalizing event comes;
    • 1 – SNMP trap is sent if specified, but the event is not logged in the alarm log.

<VALUE> – parameter value.

Command mode

CONFIG

Example

ma4000(config)# alarm redundancy-fail severity info

alarm system-reboot

This command allows to configure the event generation parameters for logging alarms while reboot the system.

The use of a negative form (no) of the command sets the default configuration.

Syntax     

alarm system-reboot <PARAM> <VALUE>
no alarm system-reboot <PARAM>

Parameters

<PARAM> – event parameter, may take values:

  • in – formation of the event when an accident occurs;
  • out – formation of event normalization at normalization of the accident;
  • severity – describes the degree of importance of the event: info, minor, major, critical;
  • ttl – time an event exists in the active alarms log. (from 1 to 2,147,483,647). Specified in seconds. It has following special values:
    • 0 – event is in the log until the normalizing event comes;
    • 1 – SNMP trap is sent if specified, but the event is not logged in the alarm log.

<VALUE> – parameter value.

Command mode

CONFIG

Example

ma4000(config)# alarm system-reboot severity info

alarmdummy

This command allows you to enable additional output of debug messages.

The full description of the functionality can be clarified by contacting the technical support service. The use of a negative form (no) of the command sets the default configuration.

show alarm configuration

This command is used to view the event settings for generating the alarm log.

Syntax     

show alarm configuration <TYPE>

Parameters

<TYPE> – event type:

Event

Description

Threshold

load-average               

Average CPU load reached the threshold, estimated time is 1 minute.


ram                        

Free RAM size decreased to the threshold.

30%

login                      

Connecting the user to the management system.


config-save

The configuration was saved on user initiative.


firmware-update            

Device firmware update.


duplicate-mac              

Two devices with the same MAC addresses detected in one VLAN.


physical-layer-flapping    

Flapping on Ethernet ports.


pon-channel-no-ont         

The first ONT connected/the last ONT disconnected on channel.


ont-physical-layer

ONT connected/disconnected.


olt-update                 

OLT chip firmware update completed successfully/with errors.


ont-update                

ONT chip firmware update completed successfully/with errors.


channel-flapping           

GPON interface flapping.


ont-flapping               

ONT flapping.


download                   

File download completed successfully/with errors.


ont-battery-power              

Switch ONT to battery power.


ont-battery-low                

ONT battery low.

Threshold is set on the ONT side.

lan-los                    

Link Down on ONT LAN port.


ont-config               

The configuration of the connected ONT is valid/not valid.


file-delete         

File deleted successfully/with errors.


physical-layer-errors

Physical layer errors on Ethernet ports.


physical-layer-block       

Ethernet port blocked.


link         

Ethernet port status changed (up/down).


logout                     

User logout from the management system.


ont-dying-gasp            

Dying Gasp signal received from ONT.


ont-rei      

Remote Error Indication (REI).


ont-power-off              

ONT power off.


config-change

OLT configuration changed.


shutdown    

SNMP agent disabled.


oms   

OMS-MIB operation completed successfully/with errors.


ont-state-changed   

ONT state changed.


ont-config-changed     

ONT configuration changed.


channel-state-changed   

GPON interface configuration changed.


pon-alarm-channel 

Event related to GPON interface.


pon-alarm-onui    

Event related to ONT.


ont-update-inprogress

Updating ONT firmware.


olt-device-reset

Resetting OLT chip.


ont-signal-degrade 

The attenuation level in the line is lower than allowed for this ONT.


high-rx-power  

The level of signal received from this ONT is above the acceptable value.

-8 dBm

free-space       

Free drive space decreased to the threshold.

30%

temperature     

The temperature has exceeded the threshold value.

60 °С

redundancy-switch

Switching to the redundant channel.


dummy

Debug message.


channel-ont-count-overflow 

The number of ONTs connected per channel exceeds the maximum allowed value (64 ONT).


ont-low-rx-power         

Input voltage is low or there is no power on one of the power feeders.


olt-device-not-working     

GPON OLT configuration was loaded successfully/with errors.


redundancy-fail          

Failure switching to the redundant channel.


fan                        

Fan rotation speed exceeded the safe operating limits.


system-reboot             

Reboot of the device.


Command mode

ROOT

Example

ma4000# show alarm configuration ram 
  Alarm:
    Severity:           major
    Send on in:         true
    Send on out:        true
    Ttl:                0
    Free space:         30%