show shelf
This command is used to view the configuration and status of the crate, installed in the crate cards.
Syntax
show shelf
Parameters
The command contains no arguments.
Command mode
ROOT
Example
ma4000# show shelf Shelf status ~~~~~~~~~~~~ Slot # Configured Type Detected Type Version Serial # Link State Slot State ------ --------------- ------------- -------- ------------------ -------- --- 0 none none 0.0.0.0 down Absent 1 none none 0.0.0.0 down Absent 2 none none 0.0.0.0 down Absent 3 none none 0.0.0.0 down Absent 4 none none 0.0.0.0 down Absent 5 plc8 plc8 3.22.0.364 OL04000854 up Operational 6 plc8 plc8 3.22.0.364 OL04001738 up Operational 7 none none 0.0.0.0 down Absent 8 none none 0.0.0.0 down Absent 9 plc8 plc8 3.22.0.364 OL04001762 up Operational 10 none none 0.0.0.0 down Absent 11 none none 0.0.0.0 down Absent 12 none none 0.0.0.0 down Absent 13 none none 0.0.0.0 down Absent 14 none none 0.0.0.0 down Absent 15 none none 0.0.0.0 down Absent
show system information
This command is used to display the status of the РР4Х management module: operation mode (uptime, CPU and memory load), temperature on 3 temperature sensors, firmware version, serial number and basic MAC address of the device.
Syntax
show system information <UNIT>
Parameters
<UNIT> – number of unit to which the PP4X module is installed, may take values [1..2].
Command mode
ROOT
Example
ma4000# show system information 1 System information (1): Uptime (d:h:m:s): 0:1:30:39 CPU load (1/5/15 minutes): 0.00/0.00/0.00 RAM (total/free), Mbytes: 498/199 Partition '/' (total/free), Mbytes: 57/22 Partition '/mnt/tools' (total/free), Mbytes: 1024/887 Partition '/mnt/config' (total/free), Mbytes: 64/61 Partition '/mnt/log' (total/free), Mbytes: 128/41 Temperature (SFP): 26C Temperature (CPU): 31C Temperature (Switch) : 44C Firmware version: 3.22.0.364 r40769 22:55:08 05/11/2014 Linux version: Linux version 2.6.22.18 (jenkins@xpon.eltex.loc) (gcc version 4.3.2 (sdk3.2rc1-ct-ng-1.4.1) ) #1 Thu Nov 6 05:20:35 NOVT 2014 MAC address: a8:f9:4b:81:85:f0 Serial number: OL02000056
show uptime
This command displays the operating time of the PP4X control module from the last reboot.
Syntax
show uptime
Parameters
The command contains no arguments.
Command mode
ROOT
Example
ma4000# show uptime up 6 days, 3:37
show system environment
This command displays the status of the basket: operation mode and fan speed, voltage and current on the device power feeders.
Syntax
show system environment [detailed]
Parameters
detailed – command used to view the full system information.
Command mode
ROOT
Example
ma4000# show system environment MFC board status: ok MFC board version: 0x2 MFC firmware: Status: 0x00 (ok) Version: 8 2 1 1 5 05/11/2013 Timestamp (UTC): 05-Nov-2013 12:19:22 Fan configured speed, %: auto Fan current speed, %: 36 Fan minimum speed, %: 15 Fan speed levels, %: 15 25 36 46 57 68 78 89 100 Fan0 Fan1 Fan2 Status: ok ok ok RPM: 2460 2442 2388 Feeder1 Feeder2 Status: ok REVERSED Current, A: 3.50 0.00 Voltage, V: -54.12 2.23 Shelf voltage, V: -54.13
fan min-speed
This command is used to set the minimum fan speed threshold of the device.
The use of a negative form (no) of the command sets the default configuration.
Syntax
fan min-speed <SPEED>
no fan min-speed
Parameters
<SPEED> – rotation speed, may take values [15..100] %.
Command mode
CONFIG
Example
ma4000(config)# fan min-speed 20
fan speed
This command is used to set a fixed fan speed for the unit or to select a speed automatically.
The use of a negative form (no) of the command sets the default configuration.
Syntax
fan speed <SPEED>
no fan speed
Parameters
<SPEED> – rotation speed, may take values [15..100/auto] %.
Command mode
CONFIG
Example
ma4000(config)# fan speed 22
fan speed-level
In the automatic adjustment mode, the fan speed changes in steps.
This command is used to set a fixed fan speed for each step of the device.
Syntax
fan speed-level <LEVEL> <SPEED>
Parameters
<LEVEL> – step number, [0..8];
<SPEED> – rotation speed, may take values [15..100/auto] %.
Command mode
CONFIG
Example
ma4000(config)# fan speed-level 5 65
fan speed-table
In the automatic adjustment mode, the fan speed changes in steps.
This command is used to set a fixed fan speed for each step of the device.
The use of a negative form (no) of the command sets the default configuration.
Syntax
fan speed-table <SPEED> <SPEED> <SPEED> <SPEED> <SPEED> <SPEED> <SPEED> <SPEED>
no fan speed-table
Parameters
<SPEED> – rotation speed, may take values [15..100/auto] %.
Command mode
CONFIG
Example
ma4000(config)# fan speed-table 17 22 33 44 55 66 77 88 99
slot type
This command is used to configure the PLC8 module in a specified slot.
The use of a negative form (no) of the command sets the default configuration for the specified slot.
Syntax
slot <SLOT> type <TYPE>
no slot <SLOT> type
Parameters
<SLOT> – slot place in the crate, may take values [0..15];
<TYPE> – board type: PLC8.
Command mode
CONFIG
Example
ma4000(config)# slot 5 type plc8
slot profile
This command is used to set the PLC8 configuration profile in a specified slot.
The use of a negative form (no) of the command sets the default configuration for the specified board.
Syntax
slot <SLOT> profile <PROFILE> <NAME>
no slot <SLOT> profile <PROFILE>
Parameters
<SLOT> – slot place in the crate, may take values [0..15];
<PROFILE> – profile type: pppoe-ia, dhcp-ra, dhcpv6-ra;
<NAME> – profile name.
Command mode
CONFIG
Example
ma4000(config)# slot 5 profile pppoe-ia pppoe-ia-00
slot terminal-vlan
This command is used to edit the parameters VLANID, CoS for terminal-vlan used in the configuration of this slot .
The use of a negative form (no) of the command sets the default configuration for the specified board.
Syntax
slot <SLOT> terminal-vlan <NAME> vid <VLAN ID> cos <COS>
no slot <SLOT> terminal-vlan <NAME>
Parameters
<SLOT> – slot place in the crate, may take values [0..15];
<NAME> – Terminal VLAN name. terminal-vlan with this name should be previously created using the terminal-vlan <NAME> command;
<VLANID> – VLAN number, may take values [1..4094];
<COS> – CoS value, [0..7, unused].
Command mode
CONFIG
Example
ma4000(config)# slot 6 terminal-vlan INTERNET vid 1123 cos unused
slot logging system loglevel
This command is used to configure the parameters of syslog message transmission to the system log for configuring this slot.
The use of a negative form (no) of the command sets the default configuration for the specified board.
Syntax
slot <SLOT> logging system loglevel <LEVEL>
no slot <SLOT> logging system
Parameters
<SLOT> – slot place in the crate, may take values [0..15];
<LEVEL> – message level, for description see Table 10.1.
Table 10.1 – Alarm message level description
Level | Description |
---|---|
emergency | Further operation of the system is not possible |
alert | The system requires emergency intervention |
critical | Critical events |
error | Operation errors |
warning | Warnings |
notice | Important events during normal operation |
info | Information messages |
debug | Debug messages |
Command mode
CONFIG
Example
ma4000(config)# slot 6 logging system loglevel debug
slot logging module
This command is used to set the syslog-message filtering level for each system module individually in the slot configuration.
The use of a negative form (no) of the command sets the default configuration for the specified board.
Syntax
slot <SLOT> logging module <TYPE> loglevel <LEVEL>
no slot <SLOT> logging module <TYPE>
Parameters
<SLOT> – slot place in the crate, may take values [0..15];
<TYPE> – system module type, for description see Table 10.2;
<LEVEL> – message level, for description see Table 10.1.
Таблица 10.2 - System module description
Module | Description |
---|---|
alarm | Alarms log message |
snmp | Messages from the SNMP agent |
pmchal-ipc | Messages from the pmchal subsystem of interprocess communication |
pmchal-gpon | GPON messages |
pmchal-machine | Messages on operation of state machines for OLT, channels, and ONT |
pmchal-olt | OLT general information |
pmchal-channel | Information about GPON channels |
pmchal-ont | ONT information |
pmchal-scheduler | Messages from the scheduler subsystem |
pmchal-rdn | Messages on GPON channels reservation |
pmchal-dhcpra | Messages from DHCP Relay Agent |
pmchal-pppoeia | Messages from PPPoE Intermediate Agent |
Command mode
CONFIG
Example
ma4000(config)# slot 6 logging module snmp loglevel info
show slot <SLOT> terminal-vlan
This command is used to view the values of vlanid and CoS for terminal-vlan used in the configuration of this slot .
Syntax
show slot <SLOT> terminal-vlan
Parameters
<SLOT> – PLC8 module number, may take values (0..15). You may specify the list of numbers using comma ( , ) or specify the range using ( - ).
Command mode
ROOT
Example
ma4000#show slot 6 terminal-vlan Terminal VLAN "t-222": VLAN ID: 222 CoS: unused
show slot <SLOT> gpon olt configuration
This command is used to view the set PPPoEIA and DHCPRA profiles used in this slot configuration.
Syntax
show slot <SLOT> gpon olt configuration
Parameters
<SLOT> – PLC8 module number, may take values (0..15). You may specify the list of numbers using comma ( , ) or specify the range using ( - ).
Command mode
ROOT
Example
ma4000#show slot 6 gpon olt configuration Profile pppoe-ia: pppoe-ia-00 OLT Profile PPPoE Intermediate Agent 0 Profile dhcp-ra: dhcp-ra-00 OLT Profile DHCP Relay Agent 0 Profile dhcp-ra per VLAN: <list is empty>
show slot <SLOT> cpu detailed1
This command is used to view information on the PLC8 linear board processor load.
Syntax
show slot <SLOT> cpu [detailed]
detailed – command that will show detailed information when specified.
Parameters
<SLOT> – PLC8 module number, may take values (0..15). You may specify the list of numbers using comma ( , ) or specify the range using ( - ).
Command mode
ROOT
Example
ma4000#show slot 6 cpu detailed
1 Not implemented in firmware version 3.34.1
show slot <SLOT> channel-group lacp
This commands are used to view the state of a channel-group of interfaces for communication with central switches PP4X.
Syntax
show slot <SLOT> channel-group lacp
Parameters
<SLOT> – PLC8 module number, may take values (0..15). You may specify the list of numbers using comma ( , ) or specify the range using ( - ).
Command mode
ROOT
Example
ma4000# show slot 6 channel-group lacp Active Aggregator: 2 Channel group 56 (Aggregator 2) Number of ports: 2 Actor System Partner System System Priority: 32768 32768 System MAC: a8:f9:4b:88:4e:60 a8:f9:4b:81:85:b0 Key: 0x0e21 0x03e1 Port plc-slot-port 6/0: [active], link up, 10 Gbps, full duplex Actor Port Partner Port Port Number: 53 23 Port Priority: 32768 32768 LACP Activity: active active Port plc-slot-port 6/1: [active], link up, 10 Gbps, full duplex Actor Port Partner Port Port Number: 54 83 Port Priority: 32768 32768 LACP Activity: active active