Дерево страниц
Перейти к концу метаданных
Переход к началу метаданных

This chapter describes the naming rules for MA4000-PX interfaces.

Access node interfaces can be divided into two groups: Ethernet interfaces and GPON interfaces. Ethernet interfaces are used for access node connection to operator's network core. GPON interfaces are used for ONT connections.

Figure 2 – Access node interface name system

For accepted access node interface name system, see Table 4.1.

Table 4.1 – Access node interface name system and numbering

Interface name

Description

Range

front-port

PP4X module external uplink interfaces

Specified as: U/P

  • U – PP4X module number [1 .. 2]
  • P – PP4X uplink interface number [0..5]

port-channel

LAG of PP4X module uplink interfaces

[1..8] – aggregation group number

slot-port

Interfaces of the PP4X module for connecting GPONPLC8 modules

Specified as: U/P

  • U – PP4X module number [1 .. 2]
  • P – interface number for PLC8 module [0..15]

slot-channel

LAG of PP4X module interfaces for PLC8 modules

[0..15] – PLC8 module number

stack-port

PP4X module internal stacking interfaces

Specified as: U/P

  • U – PP4X module number [1 .. 2]
  • P – interface number for PP4X module [0..1]

plc-slot-port

PLC8 module interfaces for connection to central switches – PP4X modules

Specified as: SP

  • S – PLC8 module number [0 .. 15]
  • P – interface number for PP4X module [0..1]

plc-slot-channel

PLC8 module interface LAG for connection to central switches – PP4X modules

[0..15] – PLC8 module number

plc-front-port

PLC8 module external management interface (mgmt)

[0..15] – PLC8 module number

plc-pon-port

PLC8 switch downlink interface connected to GPONOLT


Specified as: SP

  • S – PLC8 module number [0 .. 15]
  • P – port number [0..7]

plc-mgmt-pon-port

PLC8 switch downlink interface connected to GPONOLT designed to control

Specified as: SP

  • S – PLC8 module number [0 .. 15]
  • P – port number [0..1]

gpon-port

PLC8 module external GPON interfaces

Specified as: SP

  • S – PLC8 module number [0 .. 15]
  • P – port number [0..7]

ont

Interfaces for the subscriber-side ONT terminals

Specified as: S/P/I

  • S – PLC8 module number [0..15]
  • P  – PLC8 module port number [0..7]
  • I  – ONT interface number [0..63]