To work with IPA-ER it is recommended to use a reader with current consumption up to 200 mA or power the reader directly from the power supply.
A reader with speaker control support and passage prohibition indication is recommended.
The communication interface between the controller and the reader operates using the Wiegand protocol, various readers with NFC, MIFARE, QR, EMM, HID, etc. can be used. It is important that Wiegand support is available.
List of verified readers
| № | Name | Working with the EVI Platform | Em-Marine | Mifare | Indication hold | Commentary |
|---|---|---|---|---|---|---|
| 1 | Iron Logic Matrix-II | Yes | Yes | No | Yes | Separate contacts for controlling the green, red LED and speaker |
| 2 | Iron Logic Matrix-III | Yes | Yes | No | Yes | Separate contacts for controlling the green, red LED and speaker |
| 3 | ProxWay pw-mini-multi-ble v2 | Yes | Yes | No | Yes | Separate contacts for controlling the green, red LED and speaker |
| 4 | Smartec ST-PR043EHM | Yes | Yes | No | Yes | No hardware control of the red LED |
| 5 | AGRG AXI 2 | Yes | No | Yes | Pulse indication operation mode | Separate contacts for controlling the green, red LED and speaker |
| 6 | Sigur MR100 Lite | Yes | No | Yes | Pulse indication operation mode | Separate contacts for controlling the green, red LED and speaker |
| 7 | Novicam ER-12W | Yes | Yes | No | Yes | No hardware control of the red LED |